background image

4

Installation Instructions

3

 EXHAUST INFORMATION

WARNING -

 IN CANADA AND IN THE 

UNITED STATES, THE REQUIRED EXHAUST DUCT 

DIAMETER IS 4 in (102mm). DO NOT USE DUCT 

LONGER THAN SPECIFIED IN THE EXHAUST LENGTH 
TABLE.

8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO

• Increase the drying times and the energy cost.
• Reduce the dryer life.

‡$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

The correct exhaust installation is YOUR RESPONSIBILITY. 
Problems due to incorrect installation are not covered by the 
warranty.

Remove and discard existing plastic or metal foil transition duct 
and replace with UL listed transition duct.
The 

MAXIMUM ALLOWABLE

 duct length and number of bends 

of the exhaust system depends upon the type of duct, number 

RIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOOFRQGLWLRQV

noted below. The maximum duct length for rigid metal duct is 
shown in the table below.

• 

)RUHYHU\H[WUDƒHOERZUHGXFHWKHDOORZDEOHYHQWV\VWHPOHQJWKE\IW

• 

7ZRƒHOERZVZLOOEHWUHDWHGOLNHRQHƒHOERZ

• 

)RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHƒHOERZWRWKHFKDUW

• 

7KHWRWDOYHQWV\VWHPOHQJWKLQFOXGHVDOOWKHVWUDLJKWSRUWLRQVDQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

•  Terminate in a manner to prevent back drafts or entry of birds or other wildlife.

‡ 7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWRWKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQW

clogging.

•  Never install a screen in or over the exhaust duct. This could cause lint build up.
• 

:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types 

Recommended

No. of 90°

Elbows

Rigid

Metal

Rigid

Metal

150 Feet

135 Feet

125 Feet

115 Feet

105 Feet

125 Feet

115 Feet

105 Feet

95 Feet

85 Feet

0

1

2

3

4

Use only for short

run installations

5

95 Feet

75 Feet

EXHAUST LENGTH

FOR LONG VENT MODELS

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types 

Recommended

No. of 90°

Elbows

Rigid

Metal

Rigid

Metal

90 Feet
60 Feet
45 Feet
35 Feet
25 Feet

60 Feet
45 Feet
35 Feet
25 Feet
15 Feet

0
1
2
3
4

Use only for short

run installations

EXHAUST LENGTH

FOR NORMAL VENT MODELS

Содержание Electric Dryer 02

Страница 1: ...instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer H VXUH WR OHDYH WKHVH instructions with the customer Note to Customer Keep these instructions with your Owner s Manual for future reference HIRUH WKH ROG GU HU LV UHPRYHG IURP VHUYLFH or discarded remove the dryer door Service information and the wiring diagram are located in the control c...

Страница 2: ...EORFN PDUNHG 1 7 Attach ground wire of power cord with the green JURXQG VFUHZ KROH DERYH VWUDLQ UHOLHI EUDFNHW 7LJKWHQ DOO WHUPLQDO EORFN VFUHZV VHFXUHO 8 Properly secure power cord to strain relief 9 Reinstall the cover INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY WALL TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING TH...

Страница 3: ...minal of block and to green ground screw on cabinet UHDU 7LJKWHQ DOO WHUPLQDO EORFN VFUHZV VHFXUHO 7 Properly secure power cord to strain relief 8 Reinstall the cover WARNING NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK I UHTXLUHG E ORFDO FRGH LQVWDOO H WHUQDO JURXQG QRW SURYLGHG to grounded metal cold water pipe or other established ground determined by a qualified electrician Wire according t...

Страница 4: ...RQV DGG RQH HOERZ WR WKH FKDUW 7KH WRWDO YHQW V VWHP OHQJWK LQFOXGHV DOO WKH VWUDLJKW SRUWLRQV DQG HOERZV RI WKH V VWHP WUDQVLWLRQ GXFW LQFOXGHG EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife 7HUPLQDWLRQ VKRXOG SUHVHQW PLQLPDO UHVLVWDQFH WR WKH H KDXVW DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR PDLQWHQDQFH WR SUHYHQW cloggin...

Страница 5: ...mmended Rigid metal transition ducts reduce the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT I ULJLG PHWDO GXFW FDQQRW EH XVHG WKHQ 8 OLVWHG ÀH LEOH PHWDO VHPL ULJLG GXFWLQJ FDQ EH XVHG LW 1HYHU LQVWDOO ÀH LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU other enclosed spaces 7RWDO OHQJWK RI ÀH LEOH PHWDO GXFW VKRXOG QRW H FHHG IHHW P DUCT TAPE OR DUCT CLAMP DUCT TAPE...

Страница 6: ...HQGHG VHH LOOXVWUDWLRQV EHORZ OERZV DOORZ WKH GU HU WR VLW FORVH WR WKH ZDOO without kinking and or crushing the transition duct PD LPL LQJ GU LQJ SHUIRUPDQFH Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect WKH GU HU WR WKH KRXVH YHQW XVLQJ D ÀH LEOH PHWDO IRLO W SH GXFW 8 OLVWHG ÀH LEOH PHWDO IRLO W...

Страница 7: ...tured home 7KH YHQW GXFW PDWHULDO 0867 0 7 Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent See section 2 for electrical connection information 8 TAB LOCATION ADDING NEW DUCT GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES U HUV LQVWDOOHG LQ JDUDJHV PXVW EH HOHYDWHG LQFKHV FP DERYH WKH ÀRRU 9 Through the rear opening locate the tab in the mi...

Страница 8: ...er internal duct and elbow as shown above EXHAUST CAN BE ADDED TO LEFT OR RIGHT SIDE DUCT TAPE DUCT TAPE CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST Connect standard metal elbows and ducts to complete WKH H KDXVW V VWHP RYHU EDFN RSHQLQJ ZLWK D SODWH LW 0 DYDLODEOH IURP R...

Страница 9: ...RGRV ORV códigos y ordenanzas vigentes Nota al instalador VHJ UHVH GH GHMDU HVWDV instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual del Propietario para referencia futura QWHV GH TXH OD VHFDGRUD DQWLJXD VHD UHWLUDGD GHO VHUYLFLR R HOLPLQDGD TXtWHOH OD SXHUWD Lainformaciónsobrereparacionesyeldiagrama del cableado se encuentran en la consola de control 1R ...

Страница 10: ...D WLHUUD RUL FLR VREUH HO VRSRUWH GH DOLYLR GH WHQVLyQ MXVWH SRU UPHPHQWH WRGRV ORV WRUQLOORV GHO EORTXH WHUPLQDO MXVWH ELHQ HO FDEOH GH HQHUJtD DO DOLYLR GH WHQVLyQ 9 Vuelva a instalar la tapa ABERTURA DE CONDUCTO INTERNA PARED VERIFIQUE QUE EL REGULADOR DE TIRO DE LA CAMPANA DE SALIDA SE ABRA Y CIERRE LIBREMENTE INCLINE LA SECADORA DE COSTADO Y QUITE LAS ALMOHADILLAS DE ESPUMA PARA ENVÍO TOMÁNDO...

Страница 11: ...D ORV WRUQLOORV H WHUQRV GHO EORTXH WHUPLQDO PDUFDGR RQHFWH HO FDEOH QHXWUDO EODQFR DO FHQWUR GHO EORTXH WHUPLQDO PDUFDGR 1 VHJ UHVH GH TXH OD FLQWD GH FRQH LyQ D WLHUUD HVWp FRQHFWDGD D OD WHUPLQDO QHXWUDO FHQWUDO GHO EORTXH DO tornillo verde de conexión a tierra de la parte trasera del JDELQHWH MXVWH SRU UPHPHQWH WRGRV ORV WRUQLOORV GHO EORTXH WHUPLQDO MXVWH ELHQ HO FDEOH GH HQHUJtD DO DOLYLR GH...

Страница 12: ...VLEOH GHO VLVWHPD GH HVFDSH Dos codos de 45 deberán ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla D ORQJLWXG WRWDO GHO VLVWHPD GH HVFDSH LQFOX H WRGDV ODV SRUFLRQHV UHFWDV WRGRV ORV FRGRV GHO VLVWHPD LQFOX HQGR HO GXFWR GH transición 4 DIA 4 4 DIA 4 DIA 2 1 2 LONGITUD MÁXIMA RECOMENDADA Tipos de campana de salida Recomendado 90 Pies 60 Pies 45 Pies 35 ...

Страница 13: ...IZAR LAS OBSTRUCCIONES DE LA SALIDA LVWHQ RSFLRQHV P OWLSOHV GH LQVWDODFLyQ Seleccione el método más apropiado para su instalación RV FRQGXFWRV PiV ODUJRV DFXPXODQ SHOXVD OR TXH JHQHUD XQ riesgo potencial de incendio 1XQFD LQVWDOH XQ OWUR GHQWUR R VREUH HO FRQGXFWR GH VDOLGD VWR SURYRFDUi OD DFXPXODFLyQ GH SHOXVDV OR TXH JHQHUD un riesgo potencial de incendio 1R DUPH OD UHG GH FRQGXFWRV FRQ VXMHFL...

Страница 14: ...RQGXFWR VREUH REMHWRV D ODGRV CONDUCTODETRANSICIÓNDEMETALFLEXIBLE SEMI RÍGIDO APROBADO POR UL En instalaciones especiales puede ser necesario conectar la secadora a la ventilación doméstica utilizando un conducto GH PHWDO ÀH LEOH WLSR SDSHO GH DOXPLQLR 3XHGH XWLOL DUVH XQ FRQGXFWR GH PHWDO ÀH LEOH WLSR SDSHO GH DOXPLQLR DSUREDGR SRU 8 6Ï 2 HQ LQVWDODFLRQHV HQ ODV TXH QR SXHGHQ XVDUVH FRQGXFWRV GH ...

Страница 15: ...r la sección 2 sobre información sobre conexiones eléctricas 8 INSTALACIÓNENGARAJE SIPERMITIDO POR LOS CODIGOS LOCALES 6HFDGRUDV LQVWDODGDV HQ JDUDJHV GHEHQ VHU HOHYDGDV SXOJDGDV FP GHO QLYHO GHO SLVR 9 A través de la abertura trasera ubique la lengüeta en el medio de la base del aparato Levante la lengüeta hasta alrededor de 45 utilizando un destornillador de lados planos GIRE LA LENGÜETA HASTA 4...

Страница 16: ...ORFDO RORTXH OD VHFDGRUD HQ VX XELFDFLyQ QDO PRECAUCIÓN Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad PLACA KIT WE1M454 5 675 68 18 92 3 5 72 3 5 5 5 6 127 21 6 352 8 726 03257 17 6 Por favor vaya a www GEAppliances com o HQYLDU SRU FRUUHR VX WDUMHWD GH LQVFULSFLyQ 3DUD SUHJXQWDV VREUH OD LQVWDODFLyQ OODPH DO 88 R DQDGi ...

Отзывы: