DigitalFlow™ Multipurpose Ultrasonic Liquid Flowmeter Service Manual
9
Chapter 1. Calibration
1.6 Alarms Option Card
Alarm relays may be added to the Model DF868 by installing an
Alarms Option Card
in one (or more) of the six
expansion slots. Each option card includes three alarm relays, which are designated as A, B, and C. To test the alarm
relays, connect an ohmmeter to the option card terminal block as shown in Figure 4 below. Refer to the menu map in
Figure 6 on page 13 as a guide.
Figure 4: Typical Ohmmeter Connections
For this discussion, assume that the option card has been installed in
Slot x
.
1.6.1 Accessing the Calibration Menu
1.
Press the
[CAL]
key to enter the
Calibration Program
.
2.
Press
[Fx]
to select
Slot x
. (The option bar will include a slot listing for each installed option card.)
3.
Press
[F1]-[F3]
to select alarm relay A, B or C, respectively.
Terminal Block (Option Card)
A
NC
B
NO
A
NO
A
COM
9
1
+
–
Ohmmeter
C
NO
C
NC
B
COM
B
NC
C
COM
Содержание DigitalFlow DF868
Страница 2: ......
Страница 4: ...ii no content intended for this page proceed to next page ...
Страница 22: ...Chapter 1 Calibration DigitalFlow Multipurpose Ultrasonic Liquid Flowmeter Service Manual 14 ...
Страница 64: ......
Страница 66: ......
Страница 67: ......