Communication Segment
© 2018 Baker Hughes, a GE company – All rights reserved.
DPS 5000 Series Instruction Manual-English | 21
Default Value
0x00000000
Sub-Index
001
Description
Standard Error Field
Data Type
UNSIGNED32
Access
RO
PDO Mapping
No
Default Value
0x00000000
A.1.4 Object 1005h: COB-ID SYNC
COB-ID of the Synchronization object. The device generates a SYNC message if bit 30 is set.
The meaning of other bits is equal to the other communication objects.
OBJECT DESCRIPTION
INDEX
1005
Name
COB-ID SYNC
Object Code
Variable
Data Type
UNSIGNED32
ENTRY DESCRIPTION
Access
RW
PDO Mapping
No
Default Value
0x080
A.1.5 Object 1007h: Synchronous Window Length
It contains the length of the time window for synchronous messages in
μ
s. When not used it
is 0.
OBJECT DESCRIPTION
INDEX
1007
Name
Synchronous Window Length
Object Code
Variable
Data Type
UNSIGNED32
ENTRY DESCRIPTION
Access
RW
PDO Mapping
No
Default Value
0x00000000
Unit
μ
s
A.1.6 Object 1008h: Manufacturer Device Name
Contains the device name.