Communication Segment
© 2018 Baker Hughes, a GE company – All rights reserved.
DPS 5000 Series Instruction Manual-English | 25
ENTRY DESCRIPTION
Access
RW
PDO Mapping
No
Default Value
0x82
A.1.13 Object 1015h: Inhibit Time Emergency
Inhibit Time used for emergency message (emergency producer). The time has to be a
multiple of 100
μ
s.
OBJECT DESCRIPTION
INDEX
1015
Name
Inhibit Time Emergency
Object Code
Variable
Data Type
UNSIGNED16
ENTRY DESCRIPTION
Access
RW
PDO Mapping
No
Default Value
0x0000
A.1.14 Object 1017h: Producer Heartbeat Time
The producer heartbeat time defines the cycle time of the heartbeat. When not used, the
time is 0. The time has to be a multiple of 1 msec.
OBJECT DESCRIPTION
INDEX
1017
Name
Producer Heartbeat Time
Object Code
Variable
Data Type
UNSIGNED16
ENTRY DESCRIPTION
Access
RW
PDO Mapping
No
Default Value
0x00000000