13
List of dip-switch S3
Hp
3/4
1
2
3
5
7.5
10
15
20
S1
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
S2
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
S3
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
S4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S5
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
S6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Hp
25
30
40
50
60
75
100
125
150
200
S1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
S2
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
S3
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
S4
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
S5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ai4080
The drives are factory set, but when installing a space regulator card, remember to set dip-switch S3 according to the
above table.
5.3 Maximum cable length for encoder terminals
Cable section [mm
2
]
0.22
0.5
0.75
1
1.5
Max Length feet [m]
88 [27]
203 [62]
305 [93]
410 [125]
492 [150]
ai3130