– 56 –
Flange
Pivot Point
6. Lift up the Ventilation Motor and place it on top
of the oven as shown below
5. Remove the 2 Phillips-head screws that attach
the Ventilation Motor to the back of the oven.
View From Rear
Note:
The Ventilation Motor electrical disconnect is
located inside the Outer Cover.
7. Locate the lock tab on top of the disconnect
and position a
fl
at blade screwdriver as shown
below.
8. Using the blower opening in the Outer Cover as
a pivot point, carefully press down on the lock
tab while disconnecting the electrical connector.
Disconnect
Lock Tab
12. If motor starts up by rotating the blades,
disconnect power, pull the two yellow wires
off the Motor Capacitor, and check resistance
between the 2 yellow wires. (See
Ventilation
Motor Capacitor
.)
• If resistance is in
fi
nite, problem is with
Ventilation Motor or wiring to motor.
• If resistance is approximately 100
Ω
, replace
the Motor Capacitor.
Disassembly
To remove the Ventilation Motor:
1. Remove the oven. (See
Oven Removal
.)
Note:
In the following step, the exhaust adapter with
damper is not used on recirculating installations.
2. Remove the 2 Phillips-head screws and the
exhaust adapter with damper from the oven.
3. Remove the 3 Phillips-head screws from the
blower plate.
4. Slide the blower plate from under its retaining
fl
ange.