– 70 –
Service Test Mode
Remove any trays (metal or glass) from the oven
before starting the diagnostic mode and make sure
that the door is closed. Removing the trays will allow
you to see the operation of the Turntable Motor
and the lower ceramic heater. Closing the door will
make sure that all loads (i.e. the halogen lamps and
Magnetron) can be energized. Note that all safety
components remain active in the service mode.
To start the service/diagnostics mode press the
SPEED COOK
pad and the
KNOB
for 3 seconds. To
exit the service/diagnostics mode press the
CLEAR/
OFF
key.
Upon entering into Field Service Mode,
SERVICE
MODE Push Dial to begin
is displayed.
The control will then proceed to service mode.
1. The control shall turn on upper halogen lamps
(center) for 3.5 seconds.
2. The control shall turn on upper halogen lamps
(exterior) for 3.5 seconds.
3. The control shall turn on lower ceramic heater
for 15 seconds.
4. The control shall turn on turntable and oven
light 5.0 seconds.
5. The control shall turn on damper motor for 15
seconds.
6. The control shall turn on circulation fan and
convection heater for 15 seconds.
7. The control shall turn on Magnetron and
Magnetron Fan for 10 seconds.
• Once in the diagnostics cycle, control will start
sequentially turning on loads/elements and
advancing to the next step each time the dial is
pressed or the “step” time has elapsed.
• Before advancing to the next step the current
loads/components are turned off.
• If
CLEAR/OFF
is pressed at any time during
service mode, the control shall exit service mode
and return to normal operation.
SERVICE MODE
SERVICE MODE
COMPLETE
COMPLETE
Press dial to re-run
Press dial to re-run
Press Clear to terminate
Press Clear to terminate
SERVICE MODE
SERVICE MODE
Push Dial to begin
Push Dial to begin
8. The control shall turn on the vent fan motor at
the HIGH for 5 seconds.
9. The control shall turn on the vent fan motor at
the MEDIUM for 5 seconds.
10. The control shall turn on the vent fan motor at
the LOW setting for 5 seconds.
11. The control shall turn on the surface light at the
HIGH setting for 5 seconds.
12. The control shall turn on the surface light at the
LOW (night light) setting for 5 seconds.
After service mode is completed, the control will
display
SERVICE MODE COMPLETE. Press dial to re-
run. Press CLEAR/OFF to terminate
.
If the dial press is detected the Service Mode is
restarted from the beginning. If Clear is detected a
2-short beep signal is sounded, the Service Mode is
terminated and the Clock/Idle state returns.