– 57 –
Disconnect
Disconnect
Capacitor
• Location - The Ventilation Motor Capacitor is
located on the right side of the Air Tunnel Inlet,
to the right of the Power Supply Board. (See
Top
View
.)
• 120
VAC
• If Ventilation Motor is humming and not moving,
(but can still be hand started), check capacitor,
capacitor wiring to motor, and motor windings.
Disassembly
To remove the Vent Motor Capacitor:
1. Remove the Outer Cover. (See
Outer Cover
.)
2. Disconnect wiring to the Ventilation Motor
Capacitor.
3. Remove the Phillips-head screw that attaches
the Ventilation Motor Capacitor to the Air Tunnel
Inlet.
Ventilation Motor Capacitor
Magnetron Fan Motor
• Location
(See
Right Side View
.)
• 120
VAC
• Single
speed
• Part of the Magnetron Fan Assembly.
• The fan motor has an approximate resistance
value of:
Red to Blue/Black = 46.6
Ω
Red to Brown = 36
Ω
Brown to Blue/Black = 10.8
Ω
• For operating algorithms, see
Load Algorithm
Chart
.
• Disassembly.
(See
Disassembly
.)
Troubleshooting
1. Disconnect power to the oven.
2. Pivot the Control Panel Assembly out from the
oven. (See
Control Panel Removal
.)
3. To gain better access to components, remove
the wires that plug into the large relays on the
Relay Board.
(See
Relay Board
.)
Cut the wire tie
that the Smart Board CN103 wire harness (See
Smart Board
.) is routed through.
(
Continued Next Page
)