– 85 –
Service Diagnostic Table
FZ
Display
FF
Display
Mode
Comments
00
47
FF Fan Test
Turns the Fan on 75% Duty Cycle and Returns the RPM
00
48
FZ Fan Test
00
49
Condenser Fan Test
00
50
Ice Box Fan Test
00
51
Deli/QC Fan Test
00
52
Convertible Drawer Fan Test
00
53
FF Defrost Heater Test
Turns on the Load
00
54
Deli Pan/QC Heater Test
(30 sec max)
00
55
Isolation Valve Test
00
56
Ice Port Heater Test
00
57
Ice Duct Liner Htr/SxS Water
Valve Test
00
58
FZ Icemaker Water Valve Test
00
59
FZ Icemaker Rake Motor Test
00
60
FZ Defrost Heater Test
00
61
Compressor Relay Test
00
63
IMX Power Relay Test
(Normally Closed Relay)
00
64
FZ Icemaker Fill Tube Heater
Test
00
65
FF Door Icemaker Water Valve
Test
00
66
FF Door Icemaker Rake Motor
Test
00
67
FF Door Hot Water Valve Test
00
68
FF Door Water Valve Test
00
69
Hot Water Heater Test
(5 sec max)
00
70
Read Left FF Door Status
Returns the Input Status (0 = Closed, 1 = Open)
00
71
Read Right FF Door Status
00
72
Read FZ Door Status
00
73
Read Conv Drawer/IM Input
Status
00
74
Read FZ Icemaker Rake Status Returns the Input Status (0 = Not Home, 1 = Home)
00
75
Read FZ Icemaker Arm Status Returns the Input Status (0 = Not Full, 1 = Full)
00
76
Read FF Door Icemaker Rake
Status
Returns the Input Status (0 = Not Home, 1 = Home)
00
77
Read FF Door Icemaker Arm
Status
Returns the Input Status (0 = Not Full, 1 = Full)
00
78
Read FF Door Cold Water Cup
Switch
Returns the Input Status (0 = Not Pressed)
00
79
Read FF Door Hot Water Cup
Switch
(
Continued next page
)