CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.15.7
15.4 Glossary
Location
Term
Definition
15
CS7050 TCP/IP Module
A module that operates as an Ethernet communications module for reporting
and upload/download.
15.1
TCP/IP Reporting
A menu entry that groups TCP/IP reporting options.
15.1.1.1
IP Address
A menu option that configures the address of the selected TCP/IP receiver.
15.1.1.2
Events
A menu entry that contains all configurable events for each receiver or email
account. All partitions are enabled by default. Enabled events are formatted
into one or more messages according to pre-configured settings and sent to
the selected report destination or email address.
Select the partition(s) to include for each event report. If the partition is not
selected, no event from that partition reports via the network regardless of
what is programmed elsewhere.
15.1.1.2.1
Arm/Disarm/Alarm
A menu entry that groups the events that are reported to the selected receiver.
15.1.1.2.1.1
Alarms
A menu option that sends a report to the selected receiver when an alarm
occurs.
15.1.1.2.1.2
Alarm Restores
A menu option that sends a report to the selected receiver when the alarm has
been restored after an alarm.
15.1.1.2.1.3
Opening/Closings
A menu option that sends a report to the selected receiver stating when the
system is opened (disarmed) and closed (armed).
15.1.1.2.1.4
Zone Bypass and Restores
A menu option that sends a report to the selected receiver when a zone is
bypassed. A report is also sent when the zone is restored (un-bypassed).
15.1.1.2.2
Tamper/Trouble
A menu entry that groups together the tamper and trouble events that are
reported to the selected receiver.
15.1.1.2.2.1
Tampers and Restores
A menu option that sends a report to the selected receiver when a tamper
occurs. A report is also sent when the tamper is no longer active.
15.1.1.2.2.2
Zone Trouble and Restores
A menu option that sends a report to the selected receiver when a zone trouble
condition occurs. A report is also sent when the trouble condition is no longer
active.
15.1.1.2.2.3
Expander Trouble and Restores
A menu option that sends an expander trouble and restore report to the
selected receiver.
15.1.1.2.2.4
Siren/Phone Faults and Restores
A menu option that sends a report to the selected receiver when a siren or
phone fault occurs. A restore report is sent when the fault is fixed.
15.1.1.2.2.5
RF Sensor Lost and Restores
A menu option that sends a report to the selected receiver when an RF sensor
is missing. A restore report is sent to the central station when the receiver
receives a valid signal from the lost transmitter.
15.1.1.2.2.6
RF Low Battery and Restores
A menu option that sends a report to the selected receiver when a low battery
condition occurs in an RF sensor. A restore report is also sent when the low
battery condition is no longer active.
15.1.1.2.3
Power
A menu entry that groups the power events that are reported to the selected
receiver.
15.1.1.2.3.1
Power Trouble and Restores
A menu option that reports mains failure, mains restore, low battery and low
battery restore events to the selected receiver.
15.1.1.2.3.2
Aux Overcurrent and Restores
A menu option that sends a report to the selected receiver when too much
current is detected. A restore report is also sent when the overcurrent condition
is fixed.