CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.10.4
10.3.2 Configuring features
You can configure testing and reporting features for the CS320 power module. The following example enables a battery
test which lasts for 60 minutes and sends a report to the central station when a low battery condition occurs.
1.
Navigate with the
µ¶
keys to
CS320 Power Modules>Power Module 84>Feature Select
and press
OK
.
2.
Scroll to
Battery Test>Enabled
and press
OK
.
3.
The keypad beeps once to accept the change and returns to
Battery Test
.
4.
Scroll to
Battery Test
Time
and press
OK
.
5.
Select
60
min.
and press
OK
.
6.
The keypad beeps once to confirm the change and returns to
Battery Test
Time
.
7.
Scroll to
Reports>Low Battery>Yes
and press
OK
.
8.
The keypad beeps once to accept the change and returns to
Low Battery
.
Table 10-3: CS320 power module output events
#
Event
#
Event
#
Event
Alarms
Arm/disarm
Misc
17
Alarm Memory
21
Armed
32
Code Entry
Tests
22
Disarmed
7
Program Mode
3
Dyn Battery Test
23
Ready to Arm
0
Always On
Tampers
18
Entry
Keypads
25
Fire LED
19
Exit
29
Keypad Fire
11
Smoke Det Reset
20
Entry or Exit
30
Keypad Medical
8
Over-current
24
Not Ready to Arm
31
Keypad Panic
9
Box Tamper
Sirens
28
Keypad Beeping
10
Siren Tamper
12
Burglary Siren
27
Chime
26
Fire Trouble
13
Fire Siren
Communications
1
Mains Failure
14
Any Siren
4
Listen-in
2
Low Battery
15
Fire Sir Steady
5
Line Seizure
16
Any Sir Temporal
6
Phone Line Fault