48
12.4. Automation setup for server GPIO
The SX-3000 GPIO automation device settings can be configured from the [Devices] tab after
selecting the
“GPIO” device name. (please refer to Figure 62)
Figure 62 GPIO automation device settings.
If the output pulse width is left blank, the default value of
50ms
will be used. If a different output
pulse width is required, the value can be entered in the ‘Output Pulse Width’ setting. Click the
[Save] button to save any changes made.
12.5. Automation setup for projectors
The SX-3000 supports automation for Barco, Christie and NEC projectors. Follow the steps below
to configure a projector device in the server automation interface.
1. Click the [Add] button on the [Devices] tab and enter the name of the device. In this case,
it is “PROJECTOR”. Set the device type to “PROJECTOR” (see Figure 62).
2. Click [OK] and set up the device parameters for the projector device (see Figure 63).
3. Enter the IP address of the projector device (see Figure 62).
4. Set the correct model of the projector. The port number will automatically change to the
default automation port number for the model. If the projector is a Series 2 projector,
check the ‘Series 2’ checkbox.
5.
Enter the ‘Login’ and ‘Password’ for the projector if required.