29
LED INDICATOR LIGHTS
Three indicator lights on the LaserPro C180’s control panel are part of the system’s safety interlock
system.
•
DOOR
- The door light will illuminate when either the top lid or external pass through doors on the
LaserPro C180 are open or improperly closed.
•
POWER
- The power light will illuminate when the LaserPro C180 is powered on.
•
LASER
- The laser light will illuminate when the laser is active and in operation.
WARNING
• DO NOT attempt to remove or modify any component of the safety interlock system.
• If at any time, any of the access doors are open and the “laser” LED is illuminated,
IMMEDIATELY unplugs the laser system and contact GCC technical support for service
instructions.
• DO NOT operate the laser system if any component of the safety system is malfunctioning.
NOTE
There is an 8 seconds warm up period after the door LED is triggered for systems equipped
with Synrad laser tubes. i.e. opening the top lid or the external pass through doors of the
machine. Operator must wait for 8 seconds before the laser tube can begin to work.
A 40 seconds laser warm up period is required after the machine is turned on. A warning
will be displayed if the users tries to run a job during the 40 seconds warm up time.
DIRECTIONAL AND SELECTION BUTTONS
Directional
( / /
/
) - Four directional buttons allow you to navigate the selection cursor
through the control panel menu and adjust the value of specific settings. In general, the
/
directional buttons cycle through the various selections, while the / directional buttons adjust the
value of that particular selection.
Enter
– Confirms the current selection.
Start / Pause
– Allows you to start/pause/restart the engraving jobs, once those jobs have been
successfully loaded onto the system.
Stop
– Stops the current job.
Back
– Returns to previous screen.
Light
– Turn light on/off.
Auto Focus
– After pressing this button, the system will automatically adjust the optimal vertical focal
distance for the laser.
Manual Focus
(▲ / ▼) – To manually adjust the vertical focal distance between the laser head and
the material, you can use the ▲ / ▼ buttons to do so. Doing so will adjust the vertical height (z-axis)
of the worktable.
Содержание LaserPro C180
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 19: ...LaserPro C180 User Manual 13 3 3 Right Profile View 3 4 Left Profile View Power Switch Power Cable Inlet...
Страница 22: ......
Страница 28: ...22 LaserPro C180 User Manual 2 Run the USBSETUP EXE file right click and click Run as Administrator...
Страница 64: ...58 LaserPro C180 User Manual...
Страница 78: ......
Страница 86: ......
Страница 106: ......
Страница 107: ...LaserPro C180 User Manual 101 Chapter 9 Basic Troubleshooting 9...
Страница 109: ...LaserPro C180 User Manual 103 Chapter 10 Appendix 10 Glossary LaserPro C180 Series Specification Sheet...