74
Appendix A: Technical Information
www.gateway.com
Technical specifications for the enclosure
Operating environment
Operating
Non-operating
+40
°
F to +95
°
F (+5
°
C to +35
°
C)
-4
°
F to +158
°
F (-20
°
C to +70
°
C)
Relative humidity
Operating/non-operating
5% - 95% (non-condensing)
Power requirements
100 - 240 VAC (auto-sensing)
3.0 Amperes (maximum)
50-60 Hz
2 x 350 Watts
Dimensions (H × W × D)
3.47" × 17.65" × 20.25"
Weight (w/2 power supplies)
38.55 lbs w/o drives
58.00 lbs with twelve drives
Altitude
-200 to 10,000 feet
Number of drives supported
12 per enclosure
Total capacity
1,752 GB (146 GB Drives)
Host interface
Ultra320 SCSI
Drive interface
SCA-80 Ultra320 SCSI
I/O interface
RS-232 (Power Supply, Temperature,
and Fan monitoring)
Electromagnetic emissions requirements
(EMI)
FCC, Part 15, Class A
CISPR 22 EN55022-A
VCCI, BSMI
Safety requirements
ANSI/UL60950
CSA #950
CE compliance (EMC)
89/336/EEC EMC Directive
Shock
Operating
Non-operating
1.0 G, 2 - 50 ms
20.0 G, 2 - 20 ms
Vibration
Operating
Non-operating
5 - 500 Hz, 0.25 G (pk to pk)
5 - 500 Hz, 1.0 G (pk to pk)
Содержание 850
Страница 1: ...user sguide your Gateway 850 SCSI storage enclosure Installing Configuring...
Страница 2: ......
Страница 34: ...30 Chapter 2 Setup and Installation www gateway com...
Страница 50: ...46 Chapter 3 Monitoring Systems www gateway com...
Страница 64: ...60 Chapter 4 Troubleshooting www gateway com...
Страница 65: ...5 61 Maintenance In this chapter you will find the maintenance procedures to replace enclosure components...
Страница 76: ...72 Chapter 5 Maintenance www gateway com...
Страница 77: ...A 73 Technical Information Specifications...
Страница 84: ...80 Appendix C Safety Regulatory and Legal Information www gateway com...
Страница 87: ......
Страница 88: ...A MAN 850 SCSI JBOD USR GDE R0 8 03...