
42
Chapter 3: Monitoring Systems
www.gateway.com
4
Verify the communication parameters are as follows:
■
9600 Baud (optional 19,200)
Baud rate set by Switch 6 – up for 19,200 and down for 9,600 (verify
the setting by pressing the Alarm Reset button and noting the
condition of the Drive Status LED for Drive slot 5).
■
8 Data bits
■
1 Stop bit
■
None (parity)
■
Flow Control Off
5
At the cursor, press
C
TRL
+E
.
The Enclosure Terminal Utility menu appears.
6
Press the
5
key to select option
5) Firmware Upload
.
Содержание 850
Страница 1: ...user sguide your Gateway 850 SCSI storage enclosure Installing Configuring...
Страница 2: ......
Страница 34: ...30 Chapter 2 Setup and Installation www gateway com...
Страница 50: ...46 Chapter 3 Monitoring Systems www gateway com...
Страница 64: ...60 Chapter 4 Troubleshooting www gateway com...
Страница 65: ...5 61 Maintenance In this chapter you will find the maintenance procedures to replace enclosure components...
Страница 76: ...72 Chapter 5 Maintenance www gateway com...
Страница 77: ...A 73 Technical Information Specifications...
Страница 84: ...80 Appendix C Safety Regulatory and Legal Information www gateway com...
Страница 87: ......
Страница 88: ...A MAN 850 SCSI JBOD USR GDE R0 8 03...