39
Enclosure monitoring using VT-100 emulation
www.gateway.com
4
Verify the communication parameters are as follows:
■
9600 Baud (optional 19,200)
Baud rate set by Switch 6 – up for 19,200 and down for 9,600 (verify
the setting by pressing the Alarm Reset button and noting the
condition of the Drive Status LED for Drive slot 5).
■
8 Data bits
■
1 Stop bit
■
None (parity)
■
Flow Control Off
5
At the screen cursor, press
C
TRL
+E
. The Enclosure Terminal Utility menu
appears.
6
Press the
1
key to select option
1) Show Enclosure Environment Status
.
Содержание 850