37
Enclosure component monitoring
www.gateway.com
Drive slot status LED
LED
condition
Indication
Drive Slot 1
Off
Enclosure in single-bus mode.
Drive Slot 2
On
SCSI Host Interface.
Drive Slot 3
Off
N/A
Drive Slot 4
Off
Switch 1 (A0) is in the DOWN position.
This will set the Drive Slot SCSI IDs to ID
1, 2, 3, 4, 5, 6, 9, 10, 11, 12, 13, and 14.
It reserves IDs 0 and 7 for the HBAs, and
ID 15 for the SAF-TE processor.
Drive Slot 5
Off
Indicates that Switch 6 is in the DOWN
position which sets the BAUD rate for the
SAF-TE RS-232 serial port to 9,600.
Drive Slot 6
Off
N/A
Drive Slot 7
Off
Switch 2 (A1) is in the DOWN position.
This will set the Drive SCSI IDs of the
slots to IDs 1, 2, 3, 4, 5, 6, 9, 10, 11, 12,
13, 14. It reserves IDs 0 and 7 for the host
bus adapter, and SCSI ID 15 for the
SAF-TE processor.
Drive Slot 8
On
Switch 7 is in the UP position which sets
the Delay Start mode to be disabled.
Drive Slot 9
Off
Controller is not installed.
Drive Slot 10
Off
Switch 3 (reserved) is in the DOWN
position.
Drive Slot 11
On
Switch 8 is in the UP position which sets
the Remote Start mode to be disabled.
Drive Slot 12
Off
Controller is not installed.
Содержание 850
Страница 1: ...user sguide your Gateway 850 SCSI storage enclosure Installing Configuring...
Страница 2: ......
Страница 34: ...30 Chapter 2 Setup and Installation www gateway com...
Страница 50: ...46 Chapter 3 Monitoring Systems www gateway com...
Страница 64: ...60 Chapter 4 Troubleshooting www gateway com...
Страница 65: ...5 61 Maintenance In this chapter you will find the maintenance procedures to replace enclosure components...
Страница 76: ...72 Chapter 5 Maintenance www gateway com...
Страница 77: ...A 73 Technical Information Specifications...
Страница 84: ...80 Appendix C Safety Regulatory and Legal Information www gateway com...
Страница 87: ......
Страница 88: ...A MAN 850 SCSI JBOD USR GDE R0 8 03...