Table 2-7. Transmit Channel Suggested P Codes to Achieve Desired dB Gain
Gain
P Code
Gain
P Code
+ 6.0 dB
240
- 0.5 dB
120
+ 5.5 dB
229
-1.0 dB
114
+ 5.0 dB
217
-1.5 dB
105
+ 4.5 dB
208
-2.0 dB
100
+ 4.0 dB
197
-2.5 dB
93
+ 3.5 dB
188
- 3.0 dB
88
+ 3.0 dB
177
- 3.5 dB
82
+ 2.5 dB
170
- 4.0 dB
78
+ 2.0 dB
160
-4.5 dB
72
+ 1.5 dB
152
- 5.0 dB
68
+ 1.0 dB
145
-5.5 dB
64
+ 0.5 dB
136
-6.0 dB
60
+ 0.0 dB
128*
MUTE
0
* The factory P Code setting is 128.
Table 2-8. Receive Channel Suggested P Codes to Achieve Desired dB Gain
Gain
P Code
Gain
P Code
+ 6.0 dB
255
- 0.5 dB
120
+ 5.5 dB
242
-1.0 dB
114
+ 5.0 dB
223
-1.5 dB
107
+ 4.5 dB
215
-2.0 dB
100
+ 4.0 dB
205
-2.5 dB
95
+ 3.5 dB
192
- 3.0 dB
90
+ 3.0 dB
181
- 3.5 dB
85
+ 2.5 dB
171
- 4.0 dB
80
+ 2.0 dB
162
-4.5 dB
75
+ 1.5 dB
152
- 5.0 dB
70
+ 1.0 dB
145
-5.5 dB
67
+ 0.5 dB
136
-6.0 dB
63
+ 0.0 dB
128*
MUTE
0
* The factory P Code setting is 128.
2.7.2
S Codes
S codes appear in response to a
STATUS?
query. Like the “P” codes, they are eight-digit binary
numbers. There is one S code for the VF-40 module, S1.
A typical VF-40 response to a STATUS? query looks like this:
* OK
CHANNEL CARD 4, TYPE 142
S01 = 0 (B00000000);