Intraplex VF-40 Voice Module
2 – Functional Description & Setup
Version 1.11
2-6
GatesAir
Intraplex Products
Table 2-1. Configuration Switches
Switch#/
Position
Label
Setting
Description
SW9/1 - 6
SCB ADDRESS
Table 2-5
Set the remote access address for the module.
SW10/1 - 5
TIME SLOT
SELECT
Table 2-4
Select the desired starting time slot.
SW10/6
LBACK
UP
DOWN
NORMAL: Local loopback off.
Activate local loopback.
SW11/1
TONE
UP
1 kHz test tone disabled.
DOWN
1 kHz test tone enabled. Nominal level +3 dBm.
SW11/2
SP0
Not active. For future use.
SW11/3 & 4
TS1, TS0
Table 2-2
Select the number of active channels (1 to 4).
SW11/5
TERM
UP
DOWN
Set the module to communicate through the DI-B port in a drop
and insert multiplexer (Section 2.5 – Drop and Insert Operation).
Set the module for use in a terminal multiplexer or to
communicate through the DI-A port in a drop and insert
multiplexer.
SW11/6
SIG OFF
UP
DOWN
NORMAL: Signaling is active.
Signaling off (Transmit Only mode)
SW11/7
REMOTE
UP
DOWN
Set module for local control.
Set module for remote control.
SW11/8
SRVC / OFF
UP
DOWN
NORMAL: Module is in service.
Take the module out of service.
Table 2-2. Active Channel Selection – SW2, Positions 3 & 4
Switch Settings
Channels Active
TS1
TS0
UP
UP
Four channels active (channels 1 - 4)
UP
DOWN
Three channels active (channels 1 - 3)
DOWN
UP
Two channels active (channels 1 - 2)
DOWN
DOWN
One channel active (channel 1 only)