Intraplex VF-40 Voice Module
2 – Functional Description & Setup
Version 1.11
2-16
GatesAir
Intraplex Products
The binary representation is more useful here than the digital, as each digit of the binary number
represents the on/off status of one of the E- and M Leads (Table 2-9).
Table 2-9. Remote Status Messages (S Codes)
S
Code
Settings
7 6 5 4 3 2 1
0
Value
Description
S1
B 0 0 0 0 0 0 0
0
↑
0
1
MB-Lead for Channel 1 is idle.
MB-Lead for Channel 1 is busy.
CH1_MB
B 0 0 0 0 0 0
0
↑
0
0
1
EB-Lead for Channel 1 is idle.
Signaling is turned on and the EB-Lead for Channel 1 is busy.
CH1_EB
B 0 0 0 0 0
0
↑
0 0
0
1
MA-Lead for Channel 1 is idle.
MA-Lead for Channel 1 is busy.
CH1_MA
B
0 0 0 0
0
↑
0 0 0
0
1
EA-Lead for Channel 1 is idle.
Signaling is turned on and the EA-Lead for Channel 1 is busy.
CH1_EA
S2
B 0 0 0 0 0 0 0
0
↑
0
1
MB-Lead for Channel 2 is idle.
MB-Lead for Channel 2 is busy.
CH2_MB
B 0 0 0 0 0 0
0
↑
0
0
1
EB-Lead for Channel 2 is idle.
Signaling is turned on and the EB-Lead for Channel 2 is busy.
CH2_EB
B 0 0 0 0 0
0
↑
0 0
0
1
MA-Lead for Channel 2 is idle.
MA-Lead for Channel 2 is busy.
CH2_MA
B
0 0 0 0
0
↑
0 0 0
0
1
EA-Lead for Channel 2 is idle.
Signaling is turned on and the EA-Lead for Channel 2 is busy.
CH2_EA
S3
B 0 0 0 0 0 0 0
0
↑
0
1
MB-Lead for Channel 3 is idle.
MB-Lead for Channel 3 is busy.
CH3_MB
B 0 0 0 0 0 0
0
↑
0
0
1
EB-Lead for Channel 3 is idle.
Signaling is turned on and the EB-Lead for Channel 3 is busy.
CH3_EB
B 0 0 0 0 0
0
↑
0 0
0
1
MA-Lead for Channel 3 is idle.
MA-Lead for Channel 3 is busy.
CH3_MA
B
0 0 0 0
0
↑
0 0 0
0
1
EA-Lead for Channel 3 is idle.
Signaling is turned on and the EA-Lead for Channel 3 is busy.
CH3_EA