3-1
Intraplex Products
Section 3 – Installation
Refer to the figures and tables in the previous section as needed during installation. Power supply and
time slot considerations may affect the installation of this module into an existing multiplexer shelf.
The sections on “Channel Module Configuration Rules” and “Adding Channel Modules to Existing
Systems” in your multiplexer operation manual give more information.
3.1 Inspection
Inspect the module for shipping damage. If you have questions regarding possible equipment damage
or shipping errors, please contact GatesAir Customer Service:
●
U.S., Canada, and Latin America: +1-217-221-8200 or●
Europe, Middle East, and Africa:
Asia and Pacific Rim:
+1-217-221-8200 3.2 Configuration
1.
Install this module in an unused physical slot in the Intraplex multiplexer and make sure to
install the appropriate module adapter or cross-connect panel at the rear of the slot where you
intend to mount this module. Appendix A gives information about selecting and installing the
module adapter.
Warning!
Hot insertion or removal of a module adapter while a channel module is in place is not
recommended, as it could damage the channel module or the module adapter. To
remove a module adapter while the system is turned on (has power), first remove the
associated channel module. Similarly, to install a new channel module, first install the
module adapter and then install the module itself.
2.
Set for use in a terminal or drop and insert multiplexer using the TERM switch (SW2, position
5): UP to communicate through the DI-B port in a drop and insert multiplexer, DOWN in a
terminal multiplexer or to communicate through the DI-A port in a drop and insert multiplexer.
3.
Select the number of active voice channels using the TS0 and TS1 switches (SW2, positions 3
and 4) (Table 2-2).
4.
Select the desired starting time slot using the TIME
SLOT
SELECT switches (SW1, positions 1 -
5) (Table 2-4).
Warning!
This module requires one time slot for each active channel. Do not select a starting
time slot that would attempt to place data in a time slot higher than 24.
5.
Set the address for the module using the SCB ADDRESS switch bank (SW3) (in Table 2-4).
You do not need to perform this step unless you are using the remote access and control
capabilities of the multiplexer, but it is advisable to set each module to a different address
during installation in order to simplify the activation of remote operation in the future.
6.
After completing the above steps, set the module for local control or remote control operation:
•
For local control:
a.
Set to local control: REMOTE switch (S2, position 5) UP.
b.
Turn service on: OFF switch (S2, position 6) UP.
c.
Install the module into the shelf (Section 3.3 - Mounting).
•
For remote control operation:
a.
Set to local control: REMOTE switch (S2, position 5) UP.
b.
Turn service off: OFF switch (S2, position 6) DOWN.
c.
Install the module (Section 3.3 - Mounting).
Содержание Intraplex MA-311
Страница 2: ......
Страница 8: ......
Страница 9: ...No header here 1 2 GatesAir Intraplex Products This page is left blank intentionally ...
Страница 10: ......
Страница 37: ...No header here GatesAir A 3 Intraplex Products This page is left blank intentionally ...