19
EN
GLB mode ON=Master: OFF=Slave
To activate RFID reader on a GLB Wallbox that is stand-alone (not
connected with other GLB Wallboxes), it is important to set the
GLB-Wallbox as master (set switch SW1 (DIP 5) to ‘ON).
If several GLB-Wallboxes are connected in group, all GLB slaves
must be connected to the data link bus and be energized before
the RFID function is activated. GLB slaves that are not plugged in
or powered will not receive RFID command and remain open for
charging and the RFID function is disabled.
RFID settings, see section Web interface in this manual.
RFID for multiple GLB Wallboxes in group
A maximum of 50 GLB Wallboxes may be connected together by
a shielded twisted pair cable, which is connected to the terminal
labelled ‘Data Link’. The Data Link cable must be electrically
terminated in the first and last wallboxes, via switch SW1 (DIP
6) on the main board, see (figure 15). To verify that the master
wallbox is defined as master, ensure the switch SW1 (DIP 5) is set
to ‘ON’ mode,(figure 14).
(figure 14)
(figure 15)
DIP Switch settings for RFID reader on
individual GLB Wallbox
5
SW1
OFF
5
ON
OFF
5
ON
6
SW1
OFF
6
ON
OFF
6
ON
DIP 6: Termination resistor ‘Datalink’
ON=activated: OFF=deactivated
Assembly instructions