4. Install the load interface unit (C) on the DIN rail.
5. Dismantle the wires and connect the load interface
to the 230V AC. Refer to the electrical schedule for
all electrical connections.
6. Connect the load interface to the protection device.
NOTE
Functional Ground connection (here shown as PE) is
only recommended to use when connecting current
transformers. However, it may also contribute to Wi-Fi
performance, since antenna groundplane is enhanced.
2-pole
2-10 A
L
N
PE
8 mm
Max 1,5 mm²
Version: 1.3
51