G1000 Supplemental Maintenance Manual
Page 3-22
Textron Nav III Series
Revision 3
190-02128-04
GDL 69A SXM Software/Configuration Loading (if installed)
Follow this procedure to configure the GDL 69A SXM Receiver. Do not follow the procedures in
this section if a GDL69A SXM unit is not installed.
Rotate the large FMS knob until the Item field is highlighted, rotate the small FMS knob
to activate the drop down menu. Rotate the small FMS knob and select
“Baseline
Option
– GDL 69A SXM Installation”
and press the
ENT
key to select it.
Press the
CHK All
softkey.
In the PRODUCT window, move the cyan selection box down with the large FMS knob
to highlight the “CARD COPY” configuration check box. Press the
ENT
key to uncheck
the configuration check box.
Press the
Load
softkey.
Monitor the loading progress and verify the software load completes without errors as
indicated by the following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….COMPLETE” in the summary box.
Press the
ENT
key to acknowledge the prompt that appears in the pop-up box.
GFC 700 Software/Configuration Loading (if installed)
Follow this procedure to configure the GFC 700 Autopilot. Do not follow the procedures in this
section if the aircraft is not equipped with GFC 700.
Rotate the large FMS knob until the Item field is highlighted, rotate the small FMS knob
to activate the drop down menu. Rotate the small FMS knob and select
“Option – GFC
700 Installation
”
and press the
ENT
key to select it.
Press the
CHK All
softkey.
In the PRODUCT window, move the cyan selection box down with the large FMS knob
to highlight the “CARD COPY” configuration check box. Press the
ENT
key to uncheck
the configuration check box.
Press the
Load
softkey.
Monitor the loading progress and verify the software load completes without errors as
indicated by the following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….COMPLETE” in the summary box.
Press the
ENT
key to acknowledge the prompt that appears in the pop-up box.
Содержание G1000 NXi
Страница 61: ......