G1000 Supplemental Maintenance Manual
Page 2-6
Textron Nav III Series
Revision 3
190-02128-04
To cancel a selection, press the small FMS knob in again, deactivating the cursor. The
CLR
key may also be used to cancel a selection or deactivate the cursor.
2.8 G1000 Normal Mode
To start the G1000 system in Normal Mode:
1. With a ground power unit connected to the external power receptacle, turn ON the BAT
(battery) switch. The following G1000 equipment is powered on:
•
PFD display
•
GSU 75 ADAHRS
•
GIA #1 (NAV and COM)
•
GEA 71 Engine/Airframe Unit
2. Turn ON the AVIONICS BUS 1 and AVIONICS BUS 2 switches. The following G1000
equipment is powered on:
•
PFD (secondary power)
•
MFD
•
GSU 75 ADAHRS (secondary power)
•
GIA #1 (NAV) (secondary power)
•
GEA 71 Engine/Airframe Unit (secondary power)
•
GTS 800 Traffic System (if installed)
•
GTX Mode S/ADS-B Transponder
•
GIA #2 (NAV and COM)
•
GMA Audio Panel
•
GSA Servos
The G1000 system is now powered in the normal mode. In the normal operating mode, data
fields that are invalid have large red X’s through them. A valid field does not display a red X.
Allow the displays to initialize for approximately one minute
for the red X’s to be removed.
The PFD and MFD will function as specified in the G1000 Cockpit Reference Guide when the
system has been correctly installed and configured.
Figure 2-6, Normal Mode
Содержание G1000 NXi