G1000 Supplemental Maintenance Manual
Page 7-12
Textron Nav III Series
Revision 3
190-02128-04
1. In the ITEM window highlight
“Option – KR87 ADF Installation”
and press the
ENT
key on the PFD.
2. Press the
CLR ALL
softkey.
3. Scroll the cursor to GIA 2 configuration box, and press the
ENT
key to check the box.
4. Press
“Load”
softkey.
5. Monitor load progress. Verify software load completes without errors as indicated by the
following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….”COMPLETE” in the summary box.
6. Acknowledge the prompt by pushing the
ENT
key.
DME GIA Configuration (For GIA 2 replacement and aircraft equipped with a
DME only)
1. Scroll the cursor to the ITEM window highlight
“Option – KN63 DME Installation”
and
press the
ENT
key on the PFD.
2. Press the
CLR ALL
softkey.
3. Scroll the cursor to GIA 1 configuration box, and press the
ENT
key to check the box.
4. Press
“Load”
softkey.
5. Monitor load progress. Verify software load completes without errors as indicated by the
following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….”COMPLETE” in the summary box.
6. Acknowledge the prompt by pushing the
ENT
key.
Traffic System GIA Configuration (For GIA 1 or GIA 2 replacement and aircraft
equipped with a Traffic system only)
1. Scroll the cursor to the ITEM window and highlight
“Option – GTS 800 Installation,
without GTX 345” OR “Option – GTS 800 Installation, with GTX 345” OR “Option –
KTA870 TAS Installation”
(as applicable) and press the
ENT
key on PFD.
2. Press the
CLR ALL
softkey.
3. Scroll the cursor to GIA 1 or GIA 2 configuration box, whichever was replaced, and press
the
ENT
key to check the box.
4. Press
“Load”
softkey.
5. Monitor load progress. Verify software load completes without errors as indicated by the
following:
•
Green “PASS” in the Configuration and Software columns for each item loaded.
•
“Upload Complete………….”COMPLETE” in the summary box.
6. Acknowledge the prompt by pushing the
ENT
key.
Содержание G1000 NXi