Installation of Non-Combustible  
Counter Stands (Optional)

1.  Assemble and level counter stand as illustrated in 

the instructions found in the counter stand carton.

2.  Remove  and  discard  leveling  bolts  on  unit  to  be 

installed on a non-combustible counter stand.

3.  Place  units  in  desired  position  on  counter  stand, 

securing the first unit with 8-32 machine screws and 

flat  washers.  Insert  8-32  machine  screws  through 

the 7/32” (5 mm) diameter holes in stand into the 

nutserts in the bottom of GD Series units.

4.  Connect  banking  plates  as  described  in  section 

titled. Installation of Banking Plates.

5.  Secure last unit to counter stand with 8-32 machine 

screws and flat washers. Insert 8-32 machine screws 

through the 7/32” (5 mm) diameter holes in stand 

into nutserts in the bottom of GD Series units

Ventilation

Counter equipment must be installed in a location in 

which the facilities for ventilation permit satisfactory 

combustion of gas and proper venting. Proper ventilation 

is imperative for good operation of the appliance. The 

ideal method of ventilating counter equipment is the 

use of a properly designed ventilating canopy, which 

should extend at least 6”/152mm beyond all sides of 

the appliance (except against the wall if the canopy is a 

wall installation). This is usually part of a mechanical 

exhaust system.

Air Supply

1.  It  is  necessary  that  sufficient  room  air  ingress  be 

allowed  to  compensate  for  the  amount  of  air 

removed  by  any  ventilating  system.  Otherwise, 

a  subnormal  atmospheric  pressure  will  occur, 

affecting  the  appliance  operation  adversely  and 

causing undesirable working conditions.

2.  Appliances  shall  be  located  so  as  not  to  interfere 

with proper circulation of air within the confined 

space. All gas burners and pilots require sufficient 

air to operate.

3.  Large objects should not be placed in front of the 

appliance which might obstruct the air flow through 

the front. Do not obstruct the flow of combustion 

and ventilation air.

4.  Do not permit fans to blow directly at the appliance, 

and wherever possible, avoid open windows adjacent 

to the appliance sides and back; also wall type fans 

which create air cross-currents within the room.

INSTALLATION Continued

ADJUSTMENTS

Burner Adjustments – All Units

1.  Before making any adjustment, turn all gas valves to 

“OFF”. Remove the burner tie wires, if not already 

removed. Be sure all piping is gas tight and that air 

is purged from lines.

2.  All units are shipped from factory at burner ratings 

set for the gas specified on the rating plate at normal 

gas pressure. The only adjustment necessary is for 

that governing air.

Air  Adjustment:  If  necessary,  the  air  is  adjusted  by 

rotating the air shutter on burner. The burner must have 

enough air that the tips of the flames are not yellow, but 

not so much air that the flames will lift off the burner 

ports. Securely tighten air shutter screw so air shutter 

cannot be moved.

Содержание Enodis GD-152H

Страница 1: ...d replacement parts Garland will have no obligation with respect to any product that has been improperly installed adjusted operated or not maintained in accordance with national and local codes or in...

Страница 2: ...e harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic bers Inhalation of airborne particles of glass wool ceramic bers is known to the State of...

Страница 3: ...ustment 8 Burner Operation 8 Fryers 8 Before Operating the Fryer 8 Pilot Burner Adjustment 8 To Operate Main Burner 8 Shutdown Instructions 8 Calibration Instructions 9 Griddles 9 Lighting Instruction...

Страница 4: ...rating plate a xed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual p...

Страница 5: ...bulb shield assembly This can be accomplished with the griddle front raised and supported by the griddle prop located on the underside of the griddle plate It is important for accurate temperature co...

Страница 6: ...If necessary pressure adjustments can be made at the pressure regulator supplied on each unit 4 Have a quali ed gas technician check the gas pressure to make certain that existing gas facilities mete...

Страница 7: ...ply 1 It is necessary that su cient room air ingress be allowed to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur a ecting the...

Страница 8: ...shortening causes severe burns Never attempt to move a fryer when the frypot is full Drain frypot completely before moving fryer ADJUSTMENTS Continued Pilot Burner Adjustment 1 Turn thermostat knob to...

Страница 9: ...e manifold to the left of each griddle valve Open the pilot valve with a screwdriver and light the pilot with a match For the griddle equipped with thermostats the pilot and the main burner are contro...

Страница 10: ...om door and use a long thin straight blade screwdriver to adjust the valve Refer to Flame Size Chart Burner Operation The burner will light automatically from the pilot Turn the valve to the full ON p...

Страница 11: ...til it does 3 When the pilot is lit continue to hold the tap in for 20 seconds then release it If the pilot goes out wait for 5 minutes then repeat from step 1 4 When the pilot is established push the...

Страница 12: ...icular unit by the correct model number including pre x and su x letters and numbers and the serial or code number The rating plate a xed to the unit contains this information Regular Maintenance Ensu...

Страница 13: ...Part 4519762 01 05 Page 13 NOTES...

Страница 14: ...Part 4519762 01 05 Page 14 NOTES...

Страница 15: ...Part 4519762 01 05 Page 15 NOTES...

Страница 16: ......

Отзывы: