Part # 4519762 (01/05)
Page 7
Installation of Non-Combustible
Counter Stands (Optional)
1. Assemble and level counter stand as illustrated in
the instructions found in the counter stand carton.
2. Remove and discard leveling bolts on unit to be
installed on a non-combustible counter stand.
3. Place units in desired position on counter stand,
securing the first unit with 8-32 machine screws and
flat washers. Insert 8-32 machine screws through
the 7/32” (5 mm) diameter holes in stand into the
nutserts in the bottom of GD Series units.
4. Connect banking plates as described in section
titled. Installation of Banking Plates.
5. Secure last unit to counter stand with 8-32 machine
screws and flat washers. Insert 8-32 machine screws
through the 7/32” (5 mm) diameter holes in stand
into nutserts in the bottom of GD Series units
Ventilation
Counter equipment must be installed in a location in
which the facilities for ventilation permit satisfactory
combustion of gas and proper venting. Proper ventilation
is imperative for good operation of the appliance. The
ideal method of ventilating counter equipment is the
use of a properly designed ventilating canopy, which
should extend at least 6”/152mm beyond all sides of
the appliance (except against the wall if the canopy is a
wall installation). This is usually part of a mechanical
exhaust system.
Air Supply
1. It is necessary that sufficient room air ingress be
allowed to compensate for the amount of air
removed by any ventilating system. Otherwise,
a subnormal atmospheric pressure will occur,
affecting the appliance operation adversely and
causing undesirable working conditions.
2. Appliances shall be located so as not to interfere
with proper circulation of air within the confined
space. All gas burners and pilots require sufficient
air to operate.
3. Large objects should not be placed in front of the
appliance which might obstruct the air flow through
the front. Do not obstruct the flow of combustion
and ventilation air.
4. Do not permit fans to blow directly at the appliance,
and wherever possible, avoid open windows adjacent
to the appliance sides and back; also wall type fans
which create air cross-currents within the room.
INSTALLATION Continued
ADJUSTMENTS
Burner Adjustments – All Units
1. Before making any adjustment, turn all gas valves to
“OFF”. Remove the burner tie wires, if not already
removed. Be sure all piping is gas tight and that air
is purged from lines.
2. All units are shipped from factory at burner ratings
set for the gas specified on the rating plate at normal
gas pressure. The only adjustment necessary is for
that governing air.
Air Adjustment: If necessary, the air is adjusted by
rotating the air shutter on burner. The burner must have
enough air that the tips of the flames are not yellow, but
not so much air that the flames will lift off the burner
ports. Securely tighten air shutter screw so air shutter
cannot be moved.