10.6 Safety Precautions
CAUTION:
The battery requires special handling at end-of-life. The battery can explode or cause burns if
disassembled, charged, or exposed to water, fire or high temperature. After replacing the
battery, properly dispose of the used battery according to instructions.
There is a risk of explosion if the battery is replaced by an incorrect type. Ensure to replace
the battery with the same type.
To avoid the possibility of electric shock, all power cords must be disconnected from the
switch before starting this procedure.
CAUTION:
The fiber optic ports contain a Class 1 laser device. When the ports are disconnected, always
cover them with the provided plug. If an abnormal fault occurs, skin or eye damage may
result if in close proximity to the exposed ports.
Remove and save the fiber optic connector cover.
Insert a fiber optic cable into the ports on the network adapter bracket as shown.
10.6.1 Safety considerations for the IBS rack mounting:
A. Verify that the maximum operating ambient temperature inside a rack assembly does not
exceed 50C.
B. Verify that a sufficient clear space is provided around the IBS unit to allow sufficient air
flow for safe operation of the product. Keep 25 mm clearance on the sides of the unit.
C. Serious injury could result due to improper handling and uneven mechanical loading. Use
proper techniques to mount and secure to the rack to avoid uneven mechanical loading.
D. An external circuit breaker rated max. 20A should be provided in the building installation
(end user's responsibility).
E. Verify that the IBS unit is reliably connected to protective grounding. Connect the product
only to a grounded type socket-outlet in the building installation or in a rack. Use the
grounding stud on the rear panel to connect the product to the rack.
Version 3.5 Page 139 of 146
10.7 TFTP server installation and configuration.
10.7.1 Windows TFTP server installation and configuration
Use any TFTP server utility to create TFTP server (for example: tftpd32 which is a free utility):
1) Create \tftp directory