INSTALLATION Continued

Wall Mounted Salamanders, Cheese Melters 
or Counter Mounted Salamander or  
Cheese Melters

1.  Clearance from combustible construction must be 

six inches (6’) minimum at rear and six inches (6”) 

minimum at sides.

  Each gas appliance shall be located with respect to 

building  construction  and  other  equipment  so  as 

to permit access to the appliance. Such access and 

clearance my be necessary for service and cleaning.

2.  All models ending with suffix “C” must be fastened 

to the counter top.

3.  All models ending with suffix “W” are mounted to 

a vertical surface using the mounting kit as shown 

below. The salamanders are shipped with the wall 

mounting kit already attached to the appliance.

4.  Provisions  for  gas  connections,  bottom  or  rear, 

should  be  taken  into  consideration  at  time  of 

installation.

Ventilation and Air Supply

Proper ventilation is highly important for good operation. 

The ideal method of ventilation a Salamander Broiler is 

the use of a properly designed canopy hood which should 

extend six inches (6”) beyond all sides of the appliance 

and six (6) feet six (6) inches from the floor.
A strong exhaust fan will create a vacuum in the room, 

for an exhaust system to work properly, replacement air 

must enter the room in which the vent is located. the 

amount of air which is exhausted must equal the amount 

entering, (make-up air).
All gas burners and pilots need sufficient air to operate 

and large objects should not be placed in front or on top 

of the broiler which would obstruct the air flow through 

the front of the broiler.

FOR YOUR SAFETY never place any type of object 
on top of the salamander broiler or cheese melters. The 
top of the broiler will exceed 1000º F. It could cause 
severe burns or fire and obstruct ventilatio

n

Clearances: 

From Combustible material 6” sides and rear. A clearance 

of 0.0” to non combustible construction as sides & rear 

is acceptable, for the Salamander, The Cheese melter is 

not suitable for installation on a combustible floor.

Содержание CM36-280

Страница 1: ...rs must be performed by a Garland authorized service agent using genuine Garland replacement parts Garland will have no obligation with respect to any product that has been improperly installed adjust...

Страница 2: ...se you to carbon monoxide if not adjusted properly Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm Keep appliance area free and clea...

Страница 3: ...tion of Salamander to a Range 9 Assembly Instructions Salamander Cheese Melters M Series Salamanders Cheese Melters 9 Models IR60 280L GCM60 280 10 Models IR48 280L IR72 280L GCM48 280 GCM72 280 10 Mo...

Страница 4: ...e Sides 6 152mm Back 6 152mm Crated 39 3 4 997mm Uncrated 34 3 4 870 Natural 6 WC 15mbar Propane 11 WC 28mbar NOTE Installation clearance reductions are applicable only where local codes permit Data a...

Страница 5: ...al Fire Protection Association s standard NFPA96 This product is not approved for residential use Model Width Use With H280 Series Model Shipping Wt Lbs Kgs Entry Clearances In mm Crated Uncrated IR36...

Страница 6: ...280 220 100 GCM 72 280 240 109 20 508mm 17 3 8 441mm 31 1 4 794mm 8 3 8 213mm 5 13 32 137mm 3 1 2 89mm 15 1 2 394mm 37 3 8 949mm 37 3 8 949mm 15 1 2 394mm 3 1 2 89mm 2 1 4 57mm 19 483mm 2 51mm 34 864...

Страница 7: ...ackets Salamander front back splash is stainless steel with black baked enamel sides IR60 280L has a finished width of 60 which includes a 24 wide shelf Salamander front and back splash is stainless s...

Страница 8: ...te D The appliance and its individual shut off supplied by others must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1 2 psi 3...

Страница 9: ...to be supplied by others Installation of Salamander to a Range Model IR36 280L GCM24 280 GCM26 280 1 The back of the range must be easily accessible 2 Position the salamander on rear of the range slip...

Страница 10: ...lamander on rear of range slipping uprights into burner box sides 3 Make sure front panel is in front of stabilizer bracket on 72 range 4 Securely fasten hardware shown Upright Burner Box Side Stabili...

Страница 11: ...for good operation The ideal method of ventilation a Salamander Broiler is the use of a properly designed canopy hood which should extend six inches 6 beyond all sides of the appliance and six 6 feet...

Страница 12: ...ow red After the burners have operated for several minutes turn the valve to MIN The burner rods will no longer glow red and the flame travels back and forth on the face of the burner ceramics Burn of...

Страница 13: ...n the grid surface and get into food products Grid racks should be washed thoroughly using a wire brush and a hot mild detergent or soap solution Rinse with clear warm water Monthly Lubricate valves a...

Страница 14: ...Part 1382669 07 05 Page 14 NOTES...

Страница 15: ...Part 1382669 07 05 Page 15 NOTES...

Страница 16: ......

Отзывы: