background image

l

 

 

02-April-2010 

For INSTANT CARE 

Содержание IC2020

Страница 1: ...l 02 April 2010 For INSTANT CARE...

Страница 2: ...Mode______________________________________________________________________ 22 4 1 1 Auto Answer Incoming Phone Calls__________________________________________________ 22 4 1 2 Nurse Call _____________...

Страница 3: ...5 3 Scancom Event code___________________________________________________________ 29 5 4 IC2020 Programming Command Table___________________________________________ 31...

Страница 4: ...sec dial the Nurse line Press hold for 20 sec delay line failure prompt RED EMERGENCY BUTTON with backlight Back lit disigned for easy access at night Backlight illuminates when off hook Backlight fla...

Страница 5: ...ction Red Light ON Signal transmitted Red Light FLASH Signal trasmitted Low Battery Nurse Button LED White Blue Press once on the Nurse Button to dial the Nurse line Press and hold the Nurse button fo...

Страница 6: ...y 48 hours to fully charge the battery z The battery can be manually disconnected by the battery switch located at the bottom covered with a rubber cap z Battery Switch is set as ON by factory default...

Страница 7: ...restore if the Emergency or Nurse button is pressed or any sensor is triggered during the line failure period line failure detection will be temporarily stopped z Once line failure is restored for on...

Страница 8: ...If IC2020 responds with one long beep the Pendent is within the operation range If no signal is received within 30 sec IC2020 will exit Learning mode Step 6 If there is a 2nd Pendant Pendant 2 wished...

Страница 9: ...EMERGENCY buttons at the same time to exit Learning Mode Or if no signal is received within 30 sec IC2020 will exit Learning mode IC2020 will emit a short beep and the LED turns off to indicate the sy...

Страница 10: ...answer the incoming calls 1 Auto Answering by ring count 2 Dial in twice Ring Count disable The two options are set by Command 41 Please refer to Command 41 under section 3 2 Programming your IC2020...

Страница 11: ...usly before trying any IC2020 Command Functions Please refer to section System Configuration Entering Programming Mode z Follow the protocol below to command the IC2020 CC DTMF ACK Function Selection...

Страница 12: ...r another IC2020 will emit another short beep signaling the 1st Tel number is erased z Likewise you can erase the respective 2nd 3rd or 4th Tel Numbers by following the above procedure Command 05 06 S...

Страница 13: ...command is to program the preferred sequenced method used for reporting z Available key in options Retry Method Function Selection Alternative 0 On by One 1 z Factory default is set as 0 Alternative...

Страница 14: ...rded message see Command 50 up to a max length of 40 seconds IC2020 will emit a beep via the telephone handset signaling 20 10 sec of time remaining to alert the call Recipient While playing the voice...

Страница 15: ...on of this time out period is unchangeable and inextensible To terminate the incoming call 1 press the white NURSE button on IC2020 or 2 press DTMF 9 from the call recipient s end Command 32 Audible F...

Страница 16: ...RED EMERGENCY BUTTON is activated When pressed it will play a voice prompt Bi Bi Bi Emergency twice then send an Emergency alarm report to the Monitoring Station Command 35 Silent Mode z IC2020 can b...

Страница 17: ...the 1st 2nd ring and waits for proper Access Code default is 1111 entry followed by the key within 15 sec Upon the correct Access Code received IC2020 will then open a Full Duplex Communication to all...

Страница 18: ...per 3 sec z If a false alarm is triggered it can be cancelled within the Guard Time Delay Function Selection Result 00 INSTANT REPORTING 01 99 DELAY z Factory Default is set as 05 5 SEC N NO OT TE E...

Страница 19: ...the Central Monitoirng Station for action If no command is received after the waiting period the system will automatically return to Idle mode When 1 is selected after IC2020 has made a report to the...

Страница 20: ...is set as 4 4 Days z When the supervisory timer expires and no supervision signal is received from WTR the supervisory alarm reporting will be made z The reporting for supervisory alarm is status rep...

Страница 21: ...prompt will repeat every 1 minute and so on Function Selection Result 00 Disable No repeat 01 1 minute 02 2 minutes 03 60 3 60 minutes z Factory Default is set as 00 No repeat N NO OT TE E During the...

Страница 22: ...ess the Pendant Button within 20 sec Learning can only be completed within the signal reception range of IC2020 If no signal is received within 20 sec IC2020 will emit a long beep and automatically re...

Страница 23: ...mitter WTR 9 Pendant Transmitter WTR 9 Water Sensor WS 9 Remote IC2020TX Step 1 Enter 94 on the phone set then a short beep will be heard via the phone set Step 2 Press the learn button on the device...

Страница 24: ...21 Command 99 Exit Programming Mode z Enter 99 and after one short beep IC2020 exits the Programming Mode and returns to idle mode...

Страница 25: ...If the dialing fails IC2020 will not retry Press Nurse button can stop and cancel the dialing call at any time During the two way voice communication press the White Nurse button on Control Panel can...

Страница 26: ...uring the line failure period then a device low battery reporting will be made after the line failure is restored z After the faulty battery is replaced IC2020 will immediately send Battery Restore re...

Страница 27: ...mom help until the call is answered for Speech Reporting Method When first reporting failed and IC2020 retries z Once the first reporting succeeded and IC2020 is in progress of back up reporting the c...

Страница 28: ...will report to the Monitoring Center that help has arrived The EMERGENCY button stop flashing and return to normal backlight If the NURSE button is not pressed within 15 min the IC2020 will send anoth...

Страница 29: ...use is set as 5 sec and for same Tel Number it is set as 62 sec Retry Method Retry Circle Each Tel Phone number can be retried up to 5 times alternative and max 15 calls will be retried During the ret...

Страница 30: ...e for 1 sec after the button is released No reporting is made during Panic Alarm However while in Panic Alarm pressing either the Emergency button Red on the Remote IC2020TX or on the Control Panel IC...

Страница 31: ...sory when nurse is triggered z 333 No WTR Learnt in When the IC2020 has no WTRB learned in previously z 373 Smoke Low battery When the Smoke Detector is under Low Battery Status Green LED flashes ever...

Страница 32: ...z D 1019 Panel Low battery When IC2020 is under Low Battery status Green LED flashes every 2 sec with a beep every hour 5 3 Scancom Event code z 515555517 Panel emergency or WS Emergency When the red...

Страница 33: ...ow battery When the Low Battery status of Water Sensor WS is under Low Battery status Green LED flashes every 2 sec with 2 beeps z 553555557 WS Low battery Restore When the Low Battery status of Water...

Страница 34: ...account number 20 Bi All formats the same 0 Contact ID 1 Scancom 2 Tunstall 3 Voice 4 Speech Bi Contact ID 21 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Voice message playing 4 Speech Tel Number 1 Bi Con...

Страница 35: ...To record voice message Bi 51 Bi To play voice message Bi 52 Bi Panic mode enable disable 0 Disable 1 Enable Bi Disable 53 Bi Line Failure Detection Voice Message 00 Disable 01 1 min 02 2 mins 03 3mi...

Отзывы: