7
3. System Configuration
3.1. Entering Programming
Mode
Three IC2020 programming modes are
available: Local Programming Mode, Remote
Programming Mode, and via CTC-835
Handheld Programmer (sold separately).
3.1.1. Local Programming Mode
From Idle mode, follow the steps below to
enter Local Programming mode.
Step 1. Plug in the telephone set
into
LOCAL PROGRAMMING
jack
located on the rear side of IC2020.
Step 2.
Pick up the handset.
RED
LED
lights up.
Step 3.
Enter default ACCESS CODE, 1111
followed by
#
.
Step 4.
IC2020 will emit 2 short beeps and
the red LED starts to flash, indicating
it is in
Programming Mode.
Step 5.
Proceed to program system by
referring to the Commands in section
3.2 Programming Your IC2020
.
<
<
N
N
O
O
T
T
E
E
>
>
)
Local programming is prohibited when
AC Power fails.
)
The first digit of Access Code must be
entered within 15 seconds, otherwise
IC2020 will exit automatically.
)
Failure to enter the correct Access
Code within 2 minutes will cause
IC2020 to exit the Programming mode
automatically.
)
To exit Programming mode, enter
99
followed by
#
, or place the handset
on hook, or disconnect the
Programming telephone set.
3.1.2. Remote Programming Mode
To allow Remote Programming, there are two
options for IC2020 to answer the incoming
calls.
(1) Auto Answering by ring count
(2) Dial in twice (Ring Count disable)
The two options are set by Command #41.
Please refer to
Command 41
under section
3.2 Programming your IC2020
.
3.1.2.1. Auto Answering by Ring Count
By using Command 41, you can set the
number of rings for IC2020 to answer (
20-
Rings
is set as factory default).
Step 1.
Dial IC2020 and wait for IC2020 to
answer.
Step 2.
Enter
1111
(default 4-digit Access
Code) followed by
#
, via the phone set.
Step 3.
IC2020 will respond with two quick
beeps to indicate it is ready for
Remote Programming. The RED LED
will flash as a visual indication.
Step 4.
You are now in
Programming Mode
.
Proceed to program by referring to the
Command in section
3.2
Programming Your IC2020
.
3.1.2.2. Dial in Twice (Ring Count Disable)
If
00
is set in Command 41, it means IC2020 is
disabled to auto answer the incoming calls by
ring count. If Remote programming is required,
you will need to call IC2020 twice.
Step 1.
Dial IC2020 and hang up after first 2
rings, wait for another 8-20 sec then
call again. IC2020 will answer the call
on the first ring. You will enter the
Remote Programming Mode after the
first ring from the 2
nd
call.
Step 2.
Enter
1111
(the default 4-digit Access
Code) followed by
#
, via the phone set.
Step 3.
IC2020 will respond with two quick
beeps to indicate it is ready for
Remote Programming Commands.
The RED LED will flash as a visual
indication.
Содержание IC2020
Страница 1: ...l 02 April 2010 For INSTANT CARE...