24
4.1.9. Remote
z
This function is only available if a
Remote (IC2020TX) has been learnt in.
z
Press
the
Red button
once to dial the
Emergency line. IC2020 will play a voice
prompt “
Bi-Bi-Bi Emergency
” twice, then
send an Emergency alarm report to the
Monitoring Station.
z
Press
the
White button
once to dial the
Nurse line. IC2020 will play a voice
prompt “
Calling nurse line
” once.
4.2. Alarm Activation
z
When an alarm is triggered, IC2020 will
enter the Guard Time Delay period (see
Command 42). Both RED LED and RED
EMERGENCY BUTTON backlight turn on
steadily.
During the Guard Time period,
pressing the
NURSE
button on
IC2020, it will cancel the alarm signal
and return to Idle Mode.
If the Guard Time Delay is set as
00
,
IC2020 will dial immediately without
the voice prompt.
z
The Alarm reporting cannot be cancelled
by pressing the
NURSE
button on IC2020
after the Guard Time Delay expires.
Confirmation Beeps
z
Once Guard Time Delay expires, IC2020
will summon help based on the
programmed reporting method. A
continuous cofirmation beeping sound
(about 3 secs per beep) will be heard after
IC2020 dials out, to inform you that the
call is in progress (regardlss of Digital or
Speech Reporting Method).
z
Confirmation beeps will be heard in the
following situations:
After IC2020 dials out to summom
help until handshake (for Digital
Reporting Method)
After IC2020 dials out to summom
help until the call is answered (for
Speech Reporting Method)
When first reporting failed, and
IC2020 retries
z
Once the first reporting succeeded, and
IC2020 is in progress of back-up reporting,
the confirmation beeps will not be heard.
Digital Reporting Method
z
After the alarm reporting is successfully
received by the Monitoring Center, IC2020
will then follow the choice of Command
#38, to enter
Follow-On and/or Call-
Back
mode:
If Command #38 is set as
0
, Follow-
On, or
2
, Follow-On & Call-Back, it
will then follow its setting as in
Command #45,
Follow-On Choice
to open Two-way Voice, or, Listen-In,
or just waiting for commands.
If Command #38 is set as
1
, Call-
Back or
2
, Follow-On & Call-Back;
after alarm reporting, it will then wait
for 60 mins for Monitoring Center
Personnel to call-back after reporting.
When the Monitoring Center calls
back within this 60-minute period,
IC2020 auto-answers the call after
the 1st -2nd ring and waits for proper
Access Code (default is
1111)
entry
followed by the (
#
) key within 15 sec.
Upon the correct Access Code
received, IC2020 will then open a
Full-Duplex Communication to allow
the Call Recipient to speak to IC2020
directly. You can also use the
following DTMF command to switch
the speech mode.
Enter DTMF
(1)
to
TALK ONLY
Enter DTMF
(2)
to open
TWO-WAY
VOICE COMMUNICATION
Enter DTMF
(3)
to
LISTEN-IN ONLY
Enter DTMF
(9)
to
HANG UP
z
Follow On Operation
During the Follow-On period, the Monitoring
Center can remotely control IC2020 by the
DTMF commands below:
1. CONTACT ID FORMAT:
Enter
(2)
to open
TWO-WAY VOICE
COMMUNICATION
Enter
(1)
to
TALK ONLY
Содержание IC2020