13–10–613 SP Page 40
SECTION 5
LUBRICATION
OIL COOLER, OIL FILTER & SEPARATOR
FIGURE 5–1 – FLOW DIAGRAM – AIR/OIL SYSTEMS
A
– Compressor
B
– Oil Reservoir
C
– Oil Separator
D
– Oil Cooler
E
– Thermal Mixing Valve
F
– Oil Filter
G
– Separator to Cylinder Oil
Return Line
H. – Pressure Relief Valve
J
– Discharge Check Valve
K
– Minimum Discharge Pressure
Valve
L
– Purge Valve
M
– Pneumatic Blowdown Valve
N
– Orifice
P
– Blowdown Muffler
R
– Shuttle Valve
S
– Pressure Regulator
T
– Solenoid Valve “IVC”
U
– Solenoid Valve “IVO”
W – Check Valve
X
– Air Filter Vacuum Switch
Y
– System Pressure Transducer
Z
– Discharge Pressure Transducer
AA – Fan & Motor
BB – Water Flow Control Valve
CC – Magnetic Water Shutoff Valve
DD – Oil LIne Check Valve (Remote
Overhead Oil Cooler Only)
EE – Oil Stop Valve (Remote
Overhead Oil Cooler Only)
207EAY797
(Ref. Drawing)
COMPRESSOR OIL SYSTEM (FIGURE 5–1) cools
the compressor, lubricates moving parts and seals in-
ternal clearances in the compression chamber.
The oil inlet line is connected at the bottom of the oil res-
ervoir. Air pressure in the oil reservoir forces oil through
the oil cooler, thermostatic mixing valve, oil filter and
into the compressor main oil gallery.
The oil passes through internal passages for lubrica-
tion, cooling and sealing. The air–oil mixture is then
discharged to the oil reservoir where a large part of
the entrained oil drops out of the air stream; the air
then passes through the final oil separator where most
of the remaining oil is removed. The separated oil is re-
turned to the compressor and the air passes to the final
discharge line.
RECOMMENDED LUBRICANT – Gardner Denver
compressors are factory filled with AEON lubricants.
These lubricants are formulated to the highest quality
standards and are factory authorized, tested and ap-
proved for use in rotary screw compressors. AEON lu-
bricants are available through your authorized Gardner
Denver compressor distributor.
OIL SPECIFICATIONS – The recommended com-
pressor lubricant is Gardner Denver AEON
t
4000 Lu-
bricating Coolant which can be used for year–round op-
eration except as noted in the “High Temperature
Operation” paragraph below, or low temperature, see
“Installation for Cold Weather”, Section 2, page 12.
AEON
t
4000 Lubricating Coolant is a superior petro-
leum base lubricant formulated and containing addi-
tives for use in Gardner Denver compressors.
Содержание ELECTRA-SAVER EAYQ E
Страница 15: ...13 10 613 SP Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077 ...
Страница 16: ...13 10 613 SP Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077 ...
Страница 31: ...13 10 613 SP Page 22 FIGURE 4 2 FLOW CHART FOR SET UP PROGRAMMING ...
Страница 45: ...13 10 613 SP Page 36 FIGURE 4 10 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 204EAY797 Ref Drawing ...
Страница 48: ...13 10 613 SP Page 39 FIGURE 4 13 WIRING DIAGRAM 202EAY546 Ref Drawing ...
Страница 75: ......