11.1
ENGINEER APPENDIX 2
Reset Modes.
Two reset modes are available to the engineer. Mode 1 reset will reset all programmed
settings to factory defaults (including user and engineer codes). Mode 2 will reset the user
and engineer codes.
Reset Mode 1.
1)
Remove all power from the Gardtec Speech Dialler for at least five seconds.
2)
Re-apply power to the unit
3)
Whilst '88' is displayed (the first 8 seconds) Press 4 6 YES NO
4)
The unit will return all programmed settings to factory defaults and re-calibrate
(this may take up to one minute).
Reset Mode 2.
1)
Remove all power from the Gardtec Speech Dialler for at least five seconds.
2)
Re-apply power to the unit
3)
Whilst '88' is displayed (the first 8 seconds) Press 1 9 YES NO
4)
The unit will return user and engineer codes to factory defaults and re-calibrate
(this may take up to one minute).