To clean the battery and the battery charger:
Make sure that the surface and the contacts of the battery and the battery
charger always are clean and dry before you connect the battery charger.
Do not use running water.
v
Battery charger:
Clean the contacts and the plastic parts with a soft
and dry cloth.
v
Battery:
Occasionally clean the ventilation slots and the terminals on
the battery using a soft brush that is clean and dry.
5. STORAGE
To put into storage:
The product must be stored away from children.
1. Remove the battery.
2. Charge the battery.
3. Clean the washer, the battery and the battery charger
(see 4. MAINTENANCE).
4. Store the washer, the battery and the battery charger in a dry,
enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v
Dispose of the product through or via your municipal recycling
collection centre.
Disposal of the battery:
Li-ion
The GARDENA battery contains lithium-ion cells that should not
be disposed of with normal household waste at the end of its life.
IMPORTANT!
v
Dispose of the batteries through or via your municipal recycling
collection centre.
1. Discharge the lithium-ion cells completely (contact the GARDENA
Service).
2. Protect the contacts on the lithium-ion cells against short circuits.
3. Dispose of the lithium-ion cells properly.
6. TROUBLESHOOTING
DANGER! Risk of injury!
Eye injury and personal injury caused by high pressure
water jet.
v
Remove the battery before you troubleshoot the product.
Problem
Possible Cause
Remedy
Washer conveys no
or almost no water
Water container is empty.
v
Fill the water container.
Air is in the system.
v
Remove the lance and push
the start lever for about
30 seconds until water is
visibly pumped.
Reassemble the lance.
Air is in the system.
v
Ventilate the system at low
altitude. Then move to the
working position.
Device filter
(see 4. MAINTENANCE), suction
filter or nozzle is clogged.
v
Clean the device filter and
suction filter. Clean the
nozzles e. g. with a needle.
Pressure drop during
operation
Device filter or suction filter
is dirty.
v
Clean the device filter
and suction filter
(see 4. MAINTENANCE).
Battery charge level is too low.
v
Charge the battery.
Water is badly sucked
in from the water tank
Suction height too high.
v
Reduce the suction height.
Air is in the system.
v
Remove the lance and push
the start lever for about
30 seconds until water is
visibly pumped.
Reassemble the lance.
Problem
Possible Cause
Remedy
Water is badly sucked
in from the water tank
Device filter or suction filter
is dirty.
v
Clean the device filter
and suction filter
(see 4. MAINTENANCE).
Washer does not stop
Start lever is stuck.
v
Remove the battery and
loosen the start lever.
Washer does not start
or stops.
LED
(L1)
is flashing green
[ Fig. O4 ]
Battery is empty.
v
Charge the battery.
Washer does not start
or stops.
Error-LED
(Wp)
is illuminated
red [ Fig. O4 ]
Battery temperature is outside
the permissible temperature
range.
v
Wait until the battery
tem perature is between
0 °C – + 45 °C again.
Washer is overheated
(e. g. by direct sunlight).
v
Let the washer cool down in
a cool, shady place.
Water has entered the battery.
v
Allow the battery to dry in
a protected place.
There are drops of water or
moisture between the battery
contacts on the washer.
v
Remove the water drops /
moisture with a dry cloth.
Engine is blocked.
v
Contact the GARDENA
Service.
Nozzle partially or fully
clogged.
v
Clean the nozzle, e. g. using
a pin / needle or a piece of
wire.
Washer does not start
or stops.
Error-LED
(Wp)
is flashing red
[ Fig. O4 ]
Product is defective.
v
Contact the GARDENA
Service.
Washer does not start
or stops.
Error-LED
(Wp)
is not
illuminated [ Fig. O4 ]
Battery is not put completely
into the battery holder.
v
Put the battery completely
into the battery holder until
it audibly engages.
Battery is defective.
v
Replace the battery.
Product is defective.
v
Contact the GARDENA
Service.
Charging is not possible.
Battery charge indicator
(Lc)
is continuously illuminated
[ Fig. O3 ]
The battery is not connected
(correctly).
v
Connect the battery to
charger correctly.
Battery contacts are dirty.
v
Clean the battery contacts
(e. g. by connecting and
disconnecting the battery
several times. Replace the
battery if necessary.
Battery temperature is out-
side the permissible charging
temperature range.
v
Wait until the battery
tem perature is between
0 °C – + 45 °C again.
Battery is defective.
v
Replace the battery.
Battery charge indicator
(Lc)
is not illuminated [ Fig. O3 ]
Mains plug of the charger is
not (correctly) plugged in.
v
Insert the mains plug into the
mains socket (completely).
Socket outlet, mains cable or
charger is defective.
v
Check the mains voltage.
Let the charger be checked
if necessary by an author-
ised specialist dealer or the
GARDENA Service.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. TECHNICAL DATA
Battery Medium Pressure
Washer
Unit
Value (Art. 14800)
Rated pressure /
Max. pressure
MPa
2.4
Max. supply pressure
MPa
0.6
Suction hose length
m
5
Max. suction head
m
2
Max. Running times
(2.5Ah battery):
Soft-Clean-Mode high
Soft-Clean-Mode soft
Soft-Clean-Mode ultra soft
min.
min.
min.
15
19
38
Max. Flow rate:
Soft-Clean-Mode high
Soft-Clean-Mode soft
Soft-Clean-Mode ultra soft
l/h
l/h
l/h
250
200
100
7
EN