PP610/612 LED lighting controllers - User Manual
Set the mode of operation
RSfSm
Where:
f
output channel (1 or 2).
m
=
4 for two currents selected using input 1
5 for two currents selected using input 2
6 for four currents selected using both inputs
Set the output current
RcfCcVvEe
Where:
f
output channel (1 or 2)
c
output selection (0, 1, 2, or 3)
v
output current (in milliamps)
e
maximum current rating of the LED. This is
optional; if not required, omit
Ee
from the
command.
Note:
This command must be sent for all output selections specified
by the mode command. If a single input is selected two current
settings are needed for selections 0 and 1. If both inputs are
selected four current settings are needed for selections 0, 1, 2 and 3.
In the following example, four currents of 0.25mA, 25.7mA, 0.5A, and 1.5A
are set on output channel 1, selected using combinations of inputs
1 and 2.
RS1S6
Use both inputs for selection.
RC1C0V0.2
Current 0 = 0.25mA when input 1 is 0, and
input 2 is 0.
RC1C1V25.7
Current 1 = 25.7mA when input 1 is 0, and
input 2 is 1.
RC1C2V500
Current 2 = 500mA when input 1 is 1, and
input 2 is 0.
RC1C3V1500
Current 3 = 1.5A when input 1 is 1, and
input 2 is 1.
—
42
—