Continuative information
32
· G&D DVIVision
Continuative information
Recommendations for the twisted pair cable
The transmission of all signals of the DVIVision system is carried out through
one
twisted pair cable
(category 5e or better).
The data transmission is reliable over a distance of at least 100 metres using a regu-
lar standard twisted pair cable (category 5e or better). The distance that can actually
be achieved depends on the quality of the used cable. High-quality S-STP cables
with an AWG22 wire gauge coding can bridge a distance of up to 140 metres. Patch
cables with an AWG26 wire gauge coding can only bridge a maximum of 80
metres.
To ensure reliable operation even in environments with interference, installation
cables with at least AWG24 coding have to be used for lengths over 80 metres.
The following cables achieved the best results during test operation:
up to 140 metres: Kerpen MegaLine G12-150 S/F AWG22
up to 100 metres: G&D K-C5-HR (see
up to 80 metres: Dätwyler Uninet flex 4P, AWG26, S-STP
The connection of several segments using patch panels and connection ports is
permitted. However, connections through active network components such as
network switches, hubs or repeaters are not permitted.
Wire gauge
Cable type
Category
Recommendation
AWG22
Installation
5e, 6 or 7
up to 140 m
AWG23
Installation
5e, 6 or 7
up to 130 m
AWG24
Installation
5e, 6 or 7
up to 120 m
AWG26/27
Patch cable
5e, 6 or 7
up to 80 m
Table 2: Recommended cable lengths depending on the wire gauge
The lengths that are mentioned in the table above must be interpreted as the sum
of all segments between the devices.
Содержание DVIVision
Страница 1: ...Guntermann Drunck GmbH G D DVIVision Installation and Operating Guide...
Страница 59: ...Notes G D DVIVision 55...