Configuration
22
· G&D DVIVision
Authorising permanent activation of input lock
If no inputs are being made at the active console during the adjusted timeout of the
automatic input lock (default: 1 second), the default settings of the DVIVision
system also permit to operate the system from the other console.
If the function
Authorising permanent activation of input lock
is activated in the setup
menu, the users of the DVIVision system are enabled to permanently activate the
input lock with the key combination
Hotkey
+
Print Screen
(default:
Ctrl
+
Print Screen
).
After having pressed this key combination, the input devices of the concurrent con-
sole are deactivated. By pressing the key combination again at the active console,
both consoles are again able to operate the DVIVision system after the automatic
input lock has elapsed.
When the permanent input lock has been activated at one console, the
Scroll
LEDs
are blinking on the keyboards of both users.
How to (de)activate the
Authorising permanent activation of input lock
function:
Related topics:
Timeout of the automatic input lock
Changing the videomode of the user consoles
This function can only be (de)activated in the setup menu.
set
u
p
menu
1. Establish the connection to the DVIVision system through the terminal
emulation program.
2. Select the row
Permanent Access CPU
with the arrow keys
,
if you want to
change this setting for the local console.
Select the row
Permanent Access CON
with the arrow keys, if you want to
change this setting for the remote console.
3. Press the
Space
key (repeatedly) to (de)activate this function:
Yes
activation of the permanent input lock possible
No
activation of the permanent input lock not possible
4. After having selected the desired setting, press the
S
key to save the settings.