background image

 

TSP & Remote TSP Controller Users Manual

 

 
 

Installation 

Receiving and Unpacking 

 Check the equipment received against the packing list enclosed to insure that all items shipped have been 
received.  If there are any shortages, notify the carrier and Gamma Vacuum.  Save all packaging material for 
inspection. 

Inspect for any obvious damage.  If the equipment is damaged in any way, a claim should be filed with the carrier 
(one copy to Gamma Vacuum).  If equipment is to be retuned for inspection or repair, authorization must be 
obtained from Gamma Vacuum Prior to reshipping.  Instructions for return will be provided at that time.  

Safety Notices 

WARNING:

  GAMMA VACUUM CONTROL UNITS DESIGNED FOR ION-PUMP OPERATION 

ARE CAPABLE OF DELIVERING 7000 VDC UNDER OPEN CIRCUIT OR LOW PRESSURE 
OPERATING CONDITIONS. 

 GAMMA VACUUM PRODUCTS ARE DESIGNED AND 

MANUFACTURED TO PROVIDE PROTECTION AGAINST ELECTRICAL AND MECHANICAL 
HAZARDS FOR THE OPERATOR AND THE AREA SURROUNDING THE PRODUCT. 

 

OBSERVE ALL INFORMATION IN THIS SECTION. 

 

Installation procedures are for use by qualified and authorized personnel who have experience working with 
voltages greater than 50 volts.  To avoid personal injury, do not perform any installation or service procedures 
unless qualified to do so.  

There are no serviceable parts inside the Remote TSP Controller.  

 

Do not operate the control without a proper electrical ground or near water.  The control may be damaged and its 
safety reduced, if it is operated outside of its specifications. 

Содержание TSP

Страница 1: ...41 t 800 237 3603 f 952 445 7615 www gammavacuum com info gammavacuum com Titanium Sublimation Pump Remote TSP Pump Controller Users Manual PN 900016 Rev C Specification information is located on our...

Страница 2: ...ration 12 Description 12 Menu Display 12 TSP Configuration Config Menu 13 TSP Settings Menu 15 TSP Sublimation Screen 17 Procedures and Additional Information 18 Cold Start Procedure 18 Degassing Fila...

Страница 3: ...the filaments The titanium serves to capture chemically reactive non noble gases Sublimation requires heating of the elements which raises the vacuum system temperature temporarily raising system pres...

Страница 4: ...trol of a TSP titanium sublimation pump or NEG non evaporable getter The remote controller operates in conjunction with the DIGITEL Ion Pump Power Supply Line It has the capability of operating up to...

Страница 5: ...5 titanium 15 molybdenum alloy wire Total length of each wire mm in 219 8 6 Coiled length of wire mm in 117 4 6 Weight per filament 3 1 to 3 5g Filament life up to 20 hours depending on operating cond...

Страница 6: ...s per TSP Control Modes Manual Programmed Auto Filament Advance Disabled Next Rotate Power Control Watts or Amps Power Output max 75 Amps 1000 watts Voltage Output max 14 volts Power Ramp Rate amps se...

Страница 7: ...lowing specifications as listed in the Official Journal of the European Communities EN 50081 1 Emissions EN 55011 Class A radiated and Conducted Emissions EN 50082 1 Immunity IEC 801 2 Electrostatic D...

Страница 8: ...MMA VACUUM CONTROL UNITS DESIGNED FOR ION PUMP OPERATION ARE CAPABLE OF DELIVERING 7000 VDC UNDER OPEN CIRCUIT OR LOW PRESSURE OPERATING CONDITIONS GAMMA VACUUM PRODUCTS ARE DESIGNED AND MANUFACTURED...

Страница 9: ...ZE O CONSIDERE REEMPLAZARLO ACHTUNG SCHWERES OBJEKT ZUR VERMEIDUNG VON MUSKELZERRUNGEN ODER R CKENSCH DEN BEIM TRANSPORT GEEIGNETE HUBVORRICHTUNGEN UND HEBETECHNIKEN VERWENDEN WARNING READ AND UNDERST...

Страница 10: ...ontroller Installation Procedure The Remote TSP Controller requires a communication cable with the DIGITEL MPCe for proper operation Required Items You need the following items to install the TSP DIGI...

Страница 11: ...s in the preferred order using the M3 set screw The orientation of the wires to the connectors is not relevant for proper TSP operation and is governed by technician preference 10 Reinstall the protec...

Страница 12: ...The TSP parameters are controlled through the MPCe Menu screen The TSP functions are separated into 2 areas 1 TSP Config configuration This section displays and controls possible hardware configuratio...

Страница 13: ...ly overwritten Re Scan The Re Scan button initiates a scan of the TSP hardware and automatically sets the TSP Configuration selected based on the hardware detected In the event that a scan does not se...

Страница 14: ...etected on that high current wire filament 4 in the above example A forward slash indicates that the filament is installed but is not achieving the desired level of current This often occurs during th...

Страница 15: ...independently and maintains the set amperage for the set on time Note Degassing will activate all installed filaments TSP Settings Menu The TSP settings menu allows control over software parameters f...

Страница 16: ...advances to the next sequential filament 4 Level A when in edit mode this value determines the maximum amperage or wattage applied to the filament Amps or watts can be selected in the edit screen 5 O...

Страница 17: ...rammed and Manual Mode Once the TSP has been properly configured and the settings entered the TSP will show the appropriate parameters in the TSP firing screen This screen is entered by pressing the T...

Страница 18: ...w filaments or ones that have been up to air must be outgassed into the roughing system The following procedure forces the major gas load from the filaments out of the system A slight release of gas o...

Страница 19: ...ur 2 and three 3 3 8 silver plated gaskets for use with either a 3 or 4 filament TSP respectively Wrench a special wrench designed to prevent bending of posts during filament installation To replace t...

Страница 20: ...volts by observing product labeling This information is available on the serial number block of the unit and near the J1 connection Contact Gamma Vacuum if a change in input power is required MPC MPC...

Страница 21: ...of cycles Z ZE ZZ is the upper pressure A AE AA is the lower pressure DDD is the duration of each firing is seconds W is set to 1 to ignore pressure automatic cycle period 28 TSP OFF Disables TSP fir...

Страница 22: ...el and the controlling parameter either Amps or Watts MPCe only R XXX P R the corresponding TSP 1 or 2 XXX watts or amps P W watts or A amps 31 GET QUAL PRESSURE 1 Reads the programmed TSP qualifying...

Страница 23: ...ent 6 Single TSP 8 filament 7 Dual TSP 3 filaments 8 Dual TSP 4 filaments 88 SET IND MODE Enables and disables the TSP independent mode YES or NO 89 GET IND MODE Returns the TSP independent mode statu...

Страница 24: ...al investment To do this our service technicians require as much information as possible about the vacuum system in need of support To assist in this process please provide the following information i...

Страница 25: ...of it s products other than in accordance with proper operating and safety procedures EXCEPT AS STATED HEREIN GAMMA VACUUM MAKES NO WARRANTY EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW...

Страница 26: ...ess may result A standard restocking fee may apply Note Prior to issuance of an RMA the required documents must be submitted to Gamma Vacuum Required Documentation During a lifetime of system operatio...

Страница 27: ...defined as any substance that because of its properties is not compatible with ultra high vacuum UHV operation Some of these are silicon in the form of silicones sulfur cadmium fluorine and chlorine...

Отзывы: