background image

 

TSP & Remote TSP Controller Users Manual

 

Product Safety Labeling 

 

 

WARNING:

  

 
SHOCK HAZARD.  
CAN CAUSE 
INJURY OR 
DEATH.  REMOVE 
POWER BEFORE 
SERVICING. 

ALERTE

:

  

 
RISQUE DE CHOC.  
PEUT CAUSER DES 
BLESSURES OU LA 
MORT.  RETIRER 
LA SOURCE 
D’ALIMENTATION 
AVANT LE 
SERVICE. 

警告: 

  

点検・修理の際は 
必ず全ての電源を 
お切りください。 
使用者が感電した 
り、死亡、または 
重傷を負う危険が 
あります。 

安全警告: 

 

可 

致受

或死亡。 

修前去掉

电 

源。 

ADVERTENCIA: 

 

PELIGRO POR 
DESCARGA. PUEDE 
CAUSAR LESIÓN O 
INCLUSO LA 
MUERTE. RETIRE Y 
DESCONECTE LA 
FUENTE DE 
ALIMENTACION 
ELECTRICA, ANTES 
DE PROCEDER AL 
SERVICIO DE 
REPARACIÓN, 
MANTENIMIENTO O 
REVISION INTERNA. 

ACHTUNG: 

 

GEFAHR ELEKTRISCHER 
SCHLÄGE. VERLETZUNGS- 
ODER LEBENSGEFAHR. 
TRENNEN SIE ALLE 
ELEKTRISCHEN 
ANSCHLÜSSE VON DER 
SPANNUNGSVERSORGUNG 
BEVOR SIE ARBEITEN AN 
DEM GERÄT AUSFÜHREN 

 

 

 

 

 

 

 

 

WARNING:

  

 

 

HEAVY OBJECT.  
TO AVOID 
MUSCLE STRAIN 
OR BACK INJURY, 
USE LIFTING AIDS 
AND PROPER 
LIFTING 
TECHNIQUES 
WHEN REMOVING 

OR REPLACING

.

 

ALERTE

:  

 
OBJET LOURD.  
POUR EVITER UNE 
TENSION 
MUSCULAIRE OU 
UN MAL DE DOS, 
UTILISER DES 
AIDES ET DES 
TECHNIQUES DE 
LEVAGE 
APPROPRIEES 
POUR 
L’ENLEVEMENT  
OU LE 
DEPLACEMENT. 

警告: 

  

大変重い装置です 
。筋挫傷、背部損 
傷等を防ぐ為、移 
動や移設の際は適 
切な技術や補助機 
器等を使用してく 
ださい。 

安全警告: 

 

重物。

避免肌肉 

或背部受

, 

时请 

使用起重

设备

以及 

的起重技

。 

ADVERTENCIA: 

 

OBJETO PESADO. 
PARA EVITAR UN 
SOBRE-ESFUERZO 
MUSCULAR O DAÑO 
FÍSICO, UTILIZE LA 
AYUDA DE 
ELEVADORES Y 
TÉCNICAS 
APROPIADAS PARA 
EL MANEJO DE 
OBJETOS PESADOS, 
CUANDO LO 
TRANSPORTE, 
DESPLAZE O 
CONSIDERE 
REEMPLAZARLO. 

ACHTUNG: 

 

SCHWERES OBJEKT. ZUR 
VERMEIDUNG VON 
MUSKELZERRUNGEN 
ODER RÜCKENSCHÄDEN 
BEIM TRANSPORT 
GEEIGNETE 
HUBVORRICHTUNGEN UND 
HEBETECHNIKEN 
VERWENDEN.

 

 

 

 

 

 

 

 

 

WARNING:

  

 
READ AND 
UNDERSTAND 
OPERATOR’S 
MANUAL BEFORE 
USING THIS 
MACHINE.  
FAILURE TO 
FOLLOW 
OPERATING 
INSTRUCTIONS 
COULD RESULT IN 
INJURY OR 
DAMAGE TO 
EQUIPMENT.

 

 

ALERTE

:

  

 
LIRE ET 
COMPRENDRE LE 
MANUEL 
D’OPERATION 
AVANT D’UTILISER 
CETTE MACHINE . 
NE PAS SUIVRE 
LES 
INSTRUCTIONS 
D’OPERATION 
PEUT CAUSER DES 
BLESSURES OU 
DES DEGATS A 
L’EQUIPEMENT. 

警告: 

  

この装置を使用さ 
れる前に必ず取扱 
説明書を熟読し理 
解した上でご使用 
ください。取扱説 
明書の通り操作を 
しなかった場合、 
装置が損傷、破損 
することがありま 
す。 

安全警告: 

 

在使用这台机器前, 
请务必阅读并理解 
“操作员手册 
(指南)”。如果 
未能遵循操作步骤 
说明,将可能导致 
设备的损坏。 

ADVERTENCIA: 

 

LEA, ESTUDIE, Y 
ENTIENDA BIEN EL 
MANUAL DE 
OPERACION, ANTES 
DE USAR ESTA 
MAQUINARIA. UNA 
FALLA POR NO 
SEGUIR LAS 
INSTRUCCIONES 
OPERATIVAS, 
PUDIERA RESULTAR 
EN DAÑO O 
PERJUICO DEL 
EQUIPO. 

ACHTUNG: 

 

LESEN UND VERSTEHEN 
SIE DIE 
BEDIENUNGSANLEITUNG 
BEVOR SIE DAS GERÄT IN 
BETRIEB NEHMEN. 
FEHLBEDIENUNGEN 
KÖNNEN ZU 
VERLETZUNGEN FÜHREN 
ODER DIE AUSRÜSTUNG 
BESCHÄDIGEN.

 

 

TSP Installation Procedure 

If purchased as part of an ion pump, the TSP and corresponding shield come pre-installed.  Refer to this section if 
the TSP and shield are purchased separately. 

Required Items 

 

You need the following items to install the TSP: 

 

Cyroshroud, ambient sputter shield or suitable 2 ¾” CFF vacuum system port. 

 

2 ¾”, 3 3/8” and/or 8” CFF gaskets, washers, bolts and nut plates (provided with new equipment purchase). 

 

Corresponding wrenches for CFF bolts. 

Содержание TSP

Страница 1: ...41 t 800 237 3603 f 952 445 7615 www gammavacuum com info gammavacuum com Titanium Sublimation Pump Remote TSP Pump Controller Users Manual PN 900016 Rev C Specification information is located on our...

Страница 2: ...ration 12 Description 12 Menu Display 12 TSP Configuration Config Menu 13 TSP Settings Menu 15 TSP Sublimation Screen 17 Procedures and Additional Information 18 Cold Start Procedure 18 Degassing Fila...

Страница 3: ...the filaments The titanium serves to capture chemically reactive non noble gases Sublimation requires heating of the elements which raises the vacuum system temperature temporarily raising system pres...

Страница 4: ...trol of a TSP titanium sublimation pump or NEG non evaporable getter The remote controller operates in conjunction with the DIGITEL Ion Pump Power Supply Line It has the capability of operating up to...

Страница 5: ...5 titanium 15 molybdenum alloy wire Total length of each wire mm in 219 8 6 Coiled length of wire mm in 117 4 6 Weight per filament 3 1 to 3 5g Filament life up to 20 hours depending on operating cond...

Страница 6: ...s per TSP Control Modes Manual Programmed Auto Filament Advance Disabled Next Rotate Power Control Watts or Amps Power Output max 75 Amps 1000 watts Voltage Output max 14 volts Power Ramp Rate amps se...

Страница 7: ...lowing specifications as listed in the Official Journal of the European Communities EN 50081 1 Emissions EN 55011 Class A radiated and Conducted Emissions EN 50082 1 Immunity IEC 801 2 Electrostatic D...

Страница 8: ...MMA VACUUM CONTROL UNITS DESIGNED FOR ION PUMP OPERATION ARE CAPABLE OF DELIVERING 7000 VDC UNDER OPEN CIRCUIT OR LOW PRESSURE OPERATING CONDITIONS GAMMA VACUUM PRODUCTS ARE DESIGNED AND MANUFACTURED...

Страница 9: ...ZE O CONSIDERE REEMPLAZARLO ACHTUNG SCHWERES OBJEKT ZUR VERMEIDUNG VON MUSKELZERRUNGEN ODER R CKENSCH DEN BEIM TRANSPORT GEEIGNETE HUBVORRICHTUNGEN UND HEBETECHNIKEN VERWENDEN WARNING READ AND UNDERST...

Страница 10: ...ontroller Installation Procedure The Remote TSP Controller requires a communication cable with the DIGITEL MPCe for proper operation Required Items You need the following items to install the TSP DIGI...

Страница 11: ...s in the preferred order using the M3 set screw The orientation of the wires to the connectors is not relevant for proper TSP operation and is governed by technician preference 10 Reinstall the protec...

Страница 12: ...The TSP parameters are controlled through the MPCe Menu screen The TSP functions are separated into 2 areas 1 TSP Config configuration This section displays and controls possible hardware configuratio...

Страница 13: ...ly overwritten Re Scan The Re Scan button initiates a scan of the TSP hardware and automatically sets the TSP Configuration selected based on the hardware detected In the event that a scan does not se...

Страница 14: ...etected on that high current wire filament 4 in the above example A forward slash indicates that the filament is installed but is not achieving the desired level of current This often occurs during th...

Страница 15: ...independently and maintains the set amperage for the set on time Note Degassing will activate all installed filaments TSP Settings Menu The TSP settings menu allows control over software parameters f...

Страница 16: ...advances to the next sequential filament 4 Level A when in edit mode this value determines the maximum amperage or wattage applied to the filament Amps or watts can be selected in the edit screen 5 O...

Страница 17: ...rammed and Manual Mode Once the TSP has been properly configured and the settings entered the TSP will show the appropriate parameters in the TSP firing screen This screen is entered by pressing the T...

Страница 18: ...w filaments or ones that have been up to air must be outgassed into the roughing system The following procedure forces the major gas load from the filaments out of the system A slight release of gas o...

Страница 19: ...ur 2 and three 3 3 8 silver plated gaskets for use with either a 3 or 4 filament TSP respectively Wrench a special wrench designed to prevent bending of posts during filament installation To replace t...

Страница 20: ...volts by observing product labeling This information is available on the serial number block of the unit and near the J1 connection Contact Gamma Vacuum if a change in input power is required MPC MPC...

Страница 21: ...of cycles Z ZE ZZ is the upper pressure A AE AA is the lower pressure DDD is the duration of each firing is seconds W is set to 1 to ignore pressure automatic cycle period 28 TSP OFF Disables TSP fir...

Страница 22: ...el and the controlling parameter either Amps or Watts MPCe only R XXX P R the corresponding TSP 1 or 2 XXX watts or amps P W watts or A amps 31 GET QUAL PRESSURE 1 Reads the programmed TSP qualifying...

Страница 23: ...ent 6 Single TSP 8 filament 7 Dual TSP 3 filaments 8 Dual TSP 4 filaments 88 SET IND MODE Enables and disables the TSP independent mode YES or NO 89 GET IND MODE Returns the TSP independent mode statu...

Страница 24: ...al investment To do this our service technicians require as much information as possible about the vacuum system in need of support To assist in this process please provide the following information i...

Страница 25: ...of it s products other than in accordance with proper operating and safety procedures EXCEPT AS STATED HEREIN GAMMA VACUUM MAKES NO WARRANTY EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW...

Страница 26: ...ess may result A standard restocking fee may apply Note Prior to issuance of an RMA the required documents must be submitted to Gamma Vacuum Required Documentation During a lifetime of system operatio...

Страница 27: ...defined as any substance that because of its properties is not compatible with ultra high vacuum UHV operation Some of these are silicon in the form of silicones sulfur cadmium fluorine and chlorine...

Отзывы: