background image

 

TSP & Remote TSP Controller Users Manual

 

25 

use, prove to be defective within twelve (12) months from the date of receipt by buyer. As expendable items may 
have a life time of less than one year, their warranty is subject to reasonable service and will be replaced as 
determined by Gamma Vacuum.  All warranty claims must be brought to the attention of Gamma Vacuum within 
30 days of failure to perform.  

 

This warranty does no cover loss, damage, or defects resulting from transportation to the buyer’s facility, improper 
or inadequate maintenance by buyer, buyer supplied software or interfacing, unauthorized modifications of 
misuse, operation outside of environmental specifications for the equipment or improper site preparation and 
maintenance.

 

In-Warranty repaired or replacement parts are warranted only for the remaining unexpired portion the the original 
warranty period applicable to the parts which have been repaired or replaced. After expiration of the applicable 
warranty period, the Buyer shall be charged at Gamma Vacuum’s then current prices for parts, labor, and 
transportation.

 

Reasonable care must be used to avoid hazards. Gamma Vacuum expressly disclaims responsibility for any loss 
or damage caused by the use of it’s products other than in accordance with proper operating and safety 
procedures.

 

EXCEPT AS STATED HEREIN, GAMMA VACUUM MAKES NO WARRANTY, EXPRESSED OR IMPLIED 
(EITHER IN FACT OR BY OPERATION OF LAW), STATUTORY OR OTHERWISE: AND , EXCEPT AS STATED 
HEREIN, GAMMA VACUUM SHALL HAVE NO LIABILITY FOR SPECIAL OR CONSEQUENTIAL DAMAGES OF 
ANY KIND OR FROM ANY CAUSE ARISING OUT OF THE SALE, INSTALLATION, OR USE OF ANY OF IT’S 
PRODUCTS.  
 
Statements made by any person, including representatives of Gamma Vacuum, which are inconsistent or in 
conflict with the terms of this warranty shall not be binding upon Gamma Vacuum unless reduced to writing and 
approved by an officer of Gamma Vacuum.

 

Gamma Vacuum may at any time discharge it’s warranty as to any of it’s products by refunding the purchase 
price and taking back the products.  

Warranty Claims 

Upon notification, Gamma Vacuum will investigate Warranty Claims.  To initiate a Warranty Claim, please contact 
Gamma Vacuum directly or a representative of Gamma Vacuum.  To assist in this evaluation, please provide the 
following information in as much detail as possible:

 

 Part 

Number

 

 Serial 

Number

 

 

Detailed Description of the Vacuum System Hardware

 

 

Detailed Description of the Vacuum System Process (gas species introduced, ultimate pressure, 
operational pressure)

 

 

Detailed Reason for the Warranty Claim

 

To expedite this process, please forward this information to 

[email protected].

 

Содержание TSP

Страница 1: ...41 t 800 237 3603 f 952 445 7615 www gammavacuum com info gammavacuum com Titanium Sublimation Pump Remote TSP Pump Controller Users Manual PN 900016 Rev C Specification information is located on our...

Страница 2: ...ration 12 Description 12 Menu Display 12 TSP Configuration Config Menu 13 TSP Settings Menu 15 TSP Sublimation Screen 17 Procedures and Additional Information 18 Cold Start Procedure 18 Degassing Fila...

Страница 3: ...the filaments The titanium serves to capture chemically reactive non noble gases Sublimation requires heating of the elements which raises the vacuum system temperature temporarily raising system pres...

Страница 4: ...trol of a TSP titanium sublimation pump or NEG non evaporable getter The remote controller operates in conjunction with the DIGITEL Ion Pump Power Supply Line It has the capability of operating up to...

Страница 5: ...5 titanium 15 molybdenum alloy wire Total length of each wire mm in 219 8 6 Coiled length of wire mm in 117 4 6 Weight per filament 3 1 to 3 5g Filament life up to 20 hours depending on operating cond...

Страница 6: ...s per TSP Control Modes Manual Programmed Auto Filament Advance Disabled Next Rotate Power Control Watts or Amps Power Output max 75 Amps 1000 watts Voltage Output max 14 volts Power Ramp Rate amps se...

Страница 7: ...lowing specifications as listed in the Official Journal of the European Communities EN 50081 1 Emissions EN 55011 Class A radiated and Conducted Emissions EN 50082 1 Immunity IEC 801 2 Electrostatic D...

Страница 8: ...MMA VACUUM CONTROL UNITS DESIGNED FOR ION PUMP OPERATION ARE CAPABLE OF DELIVERING 7000 VDC UNDER OPEN CIRCUIT OR LOW PRESSURE OPERATING CONDITIONS GAMMA VACUUM PRODUCTS ARE DESIGNED AND MANUFACTURED...

Страница 9: ...ZE O CONSIDERE REEMPLAZARLO ACHTUNG SCHWERES OBJEKT ZUR VERMEIDUNG VON MUSKELZERRUNGEN ODER R CKENSCH DEN BEIM TRANSPORT GEEIGNETE HUBVORRICHTUNGEN UND HEBETECHNIKEN VERWENDEN WARNING READ AND UNDERST...

Страница 10: ...ontroller Installation Procedure The Remote TSP Controller requires a communication cable with the DIGITEL MPCe for proper operation Required Items You need the following items to install the TSP DIGI...

Страница 11: ...s in the preferred order using the M3 set screw The orientation of the wires to the connectors is not relevant for proper TSP operation and is governed by technician preference 10 Reinstall the protec...

Страница 12: ...The TSP parameters are controlled through the MPCe Menu screen The TSP functions are separated into 2 areas 1 TSP Config configuration This section displays and controls possible hardware configuratio...

Страница 13: ...ly overwritten Re Scan The Re Scan button initiates a scan of the TSP hardware and automatically sets the TSP Configuration selected based on the hardware detected In the event that a scan does not se...

Страница 14: ...etected on that high current wire filament 4 in the above example A forward slash indicates that the filament is installed but is not achieving the desired level of current This often occurs during th...

Страница 15: ...independently and maintains the set amperage for the set on time Note Degassing will activate all installed filaments TSP Settings Menu The TSP settings menu allows control over software parameters f...

Страница 16: ...advances to the next sequential filament 4 Level A when in edit mode this value determines the maximum amperage or wattage applied to the filament Amps or watts can be selected in the edit screen 5 O...

Страница 17: ...rammed and Manual Mode Once the TSP has been properly configured and the settings entered the TSP will show the appropriate parameters in the TSP firing screen This screen is entered by pressing the T...

Страница 18: ...w filaments or ones that have been up to air must be outgassed into the roughing system The following procedure forces the major gas load from the filaments out of the system A slight release of gas o...

Страница 19: ...ur 2 and three 3 3 8 silver plated gaskets for use with either a 3 or 4 filament TSP respectively Wrench a special wrench designed to prevent bending of posts during filament installation To replace t...

Страница 20: ...volts by observing product labeling This information is available on the serial number block of the unit and near the J1 connection Contact Gamma Vacuum if a change in input power is required MPC MPC...

Страница 21: ...of cycles Z ZE ZZ is the upper pressure A AE AA is the lower pressure DDD is the duration of each firing is seconds W is set to 1 to ignore pressure automatic cycle period 28 TSP OFF Disables TSP fir...

Страница 22: ...el and the controlling parameter either Amps or Watts MPCe only R XXX P R the corresponding TSP 1 or 2 XXX watts or amps P W watts or A amps 31 GET QUAL PRESSURE 1 Reads the programmed TSP qualifying...

Страница 23: ...ent 6 Single TSP 8 filament 7 Dual TSP 3 filaments 8 Dual TSP 4 filaments 88 SET IND MODE Enables and disables the TSP independent mode YES or NO 89 GET IND MODE Returns the TSP independent mode statu...

Страница 24: ...al investment To do this our service technicians require as much information as possible about the vacuum system in need of support To assist in this process please provide the following information i...

Страница 25: ...of it s products other than in accordance with proper operating and safety procedures EXCEPT AS STATED HEREIN GAMMA VACUUM MAKES NO WARRANTY EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW...

Страница 26: ...ess may result A standard restocking fee may apply Note Prior to issuance of an RMA the required documents must be submitted to Gamma Vacuum Required Documentation During a lifetime of system operatio...

Страница 27: ...defined as any substance that because of its properties is not compatible with ultra high vacuum UHV operation Some of these are silicon in the form of silicones sulfur cadmium fluorine and chlorine...

Отзывы: