SAVE THESE INSTRUCTIONS
19
Closed
Position 5
Function: Cleaning the hair and lint strainer.
This position stops the flow of water into the
pump and filter.
CAUTION: Do not run pump with valve in
this position.
Purge/
Drain
Position 6
Function: bypass the filter. This position
is ideal for vacuuming pools with large
amounts of debris or after an algae treat-
ment. In this position, water bypasses
the filter and sends all the water and
contaminates out the waste line.
Winterize
Position 7
Function: winterizing and storage. In this
position, the valve lever is between positions
which removes pressure from internal valve
components for winter (off-season) storage.
CAUTION: Do not run pump with valve in
this position.
Changing Valve Positions
The 7 Position Multi-Port Valve is designed to give the required flow rate for each
action that is described above. Always make sure the power source to the filter is
unplugged before changing valve positions. In other words, the pump should not
be running when you change valve settings (i.e. moving from Filtration position to
the Backwash position). Changing valve positions while the pump is running could
result in irreparable damage to the valve and its inner workings. To change valve
positions, press down firmly on the valve lever and rotate to the desired setting.
ImPoRtANt
ALWAYS unplug power source to pump before changing valve positions.
cAUtIoN
NEVER use the valve lever as a handle to carry or lift the filter.