SAVE THESE INSTRUCTIONS
23
11. tRoUbLEShootINg
Problem
Cause
Solution
Pressure gauge
has reading over
15 psi
Dirty filter bed
Backwash the filter
(position 4)
Pressure is too
low
Hair and lint strainer basket
is dirty
Clean the hair and lint
strainer
Air in the pump
Poor seal on the intake side
of the pump.
Tighten hose clamps and
connecting fittings.
Water flows into
the drainpipe
Dirt around the seal of the
Central Valve
Unscrew the central valve
from tank cover and clean
the seal
Leaking filter
Seal Defective
Check the seal, replace if
needed
Pump does not
run
Not plugged in
Check the socket and power
cord
G.F.C.I/ or main circuit breaker
tripped
Switch on the breaker (if it is
immediately tripped again,
there is a defect in pump or
controls)
Pump motor defective
Replace the entire pump
Sand in Pool
If the sand is newly replaced,
the undersized grains are still
present
Backwash several times until
the backwash water is clear
(position 4)
Sand in central valve (from
backwash)
Purge into drainpipe for 30
seconds (position 6)
Separation wall in filter is
improperly installed
Check the separation wall for
proper positioning
Filter bottom strainer is
damaged
Replace the filter bottom
strainer
Air in system
Loosen, but do not remove,
the transparency cover
on the filter tank to allow
any trapped air to escape.
Tighten the cover once all
of the air has escaped.
StoP
Repairs on the pump should only be performed by professionally
trained, qualified technicians.
Содержание AQUAQUIK 4510