11
V OPERATION
This hood has been designed to avoid condensation on its lower surfaces when it is placed on top of an induction hob.
Unlike the gas hob, the induction hob only heats the pots and not the surrounding air, so the surfaces of the hood
remain cold.
When hot cooking fumes rise, they meet the cold surfaces of the hood, condense and release the humidity present in
the air which quickly transforms into water droplets that inevitably fall on the hob and food, dragging fat and impurities.
To avoid this problem, all the lower surfaces of the hood are heated by a system of internal heating elements (not
visible), therefore the heating of the lower surfaces of the hood, even without turning on the hob below, is perfectly
normal and is not a signal of a malfunction of the product.
The controls (Fig. 5.1) are equipped with keys for turning on the TL lamp; for starting the blower and selecting the
operating speeds T1, T2, T3, and T4. When the T1 key is pressed, the blower starts at 1
st
speed.
Keys T1, T2, T3, and T4 select 2
nd
, 3
rd
, and 4
th
speed levels respectively.
The L1, L2, L3, and L4 LEDs indicate the set level.
The anti-condensation function is activated automatically when the hood is switched on. The T5 key switches off (or
reactivates) the anti-condensation function without switching off the blower. The red LR LED on indicates that the
anti-condensation function is active.
To switch off the blower, press T1: once, when at 1
st
level; twice for 2
nd
, 3
rd,
and 4
th
level.
The internal grease filter is not heated by purpose, to allow condensation of much of the moisture in the air, so drops
can form on this surface and will be collected in the special lower tray. As soon as the cooking section is over it is
recommended to check whether or not there is water in the tray. The absence of water in the tray is not a sign of the
incorrect operation of the product. To empty the tray, simply push the discharge lever on the front and at the same
time place a container under the discharge valve in the center of the tray to collect the liquids (Fig. 5.2)
The hood is equipped with a multi-speed motor. It is recommended to turn on the hood a few minutes before starting
to cook to allow the lower surfaces to heat up and keep it running until the odors disappear.
While cooking, it is recommended to always use the maximum suction speed of the hood to obtain maximum
performance both in terms of suction and reduction condensation.
V.1 Adjustable and delayed self-switching off
To activate the auto-off, you must turn on the hood at the desired speed, then press and hold the speed button
corresponding to the minutes of auto-off you want to set until it flashes, as follows:
T1 corresponds to 5 minutes; T2 corresponds to 10 minutes, T3 corresponds to 15 minutes.
While the self-switching off is activated, it is possible to modify the speed previously set.
If the selected switch-off time
corresponds to the set speed, the speed LED flashes, if the choice is different the speed LED remains fixed.
V.2 Maintenance reminder
Metal anti-grease filters
Once the hood is switched off, after 30-hour functioning, all the LEDs of the speed buttons switch on with a fixed light
for 30 seconds to remind that the anti-grease metal filter needs cleaning. To set the timer to zero keep the button T1
(Fig. 5.1) pressed with the aspirator switched off, otherwise the timer will remain set on 30-hour functioning and the
reminder will appear when the hood is switched off again.
Activated anti-odor charcoal filter (for ductless hoods)
Every 120 hours of operation, when the hood is switched off, all the LEDs of the speed buttons turn on with a flashing
light for 30 sec. as a reminder of the replacement of the activated anti-odor charcoal filters and the metal anti-grease
filters cleaning. To reset the timer, simply hold the T1 key down (Fig. 5.1) with the blower off, otherwise, the alarm
will appear again the next time the hood is switched off.
Condensate tray full warning
An internal electronic sensor immediately switches off the hood and turns on the speed LEDs in sequence when the
water in the condensation tray reaches the maximum level. To reset the warning and be able to restart the hood, it is
essential to empty the condensation collection tray, as described in the OPERATION paragraph.
VI MAINTENANCE AND CLEANING
Warning! Before any maintenance or cleaning operation, disconnect the hood from the power
supply by setting the main switch of the domestic system to "off".