VACSOUND ECO – Operating and maintenance instructions
28
Unscheduled maintenance
Card No.
103
Pump type:
VACSOUND ECO D12, D18, D28
Frequency:
when damaged
Time:
30 min.
Machine
status:
S
Type of action:
Disassembly
Item:
Sight glass
Materials required
Equipment required
•
OR gaskets (kit p/n 985700212001)
•
Sight glass
Mechanical tools
WARNING
: Machine safety: disconnect all power lines. Hang the card “MACHINE
UNDERGOING MAINTENANCE - DO NOT POWER ON” from the main breaker switch. When
finished, remove the safety warning.
WARNING
: If you have to perform maintenance on the pump after a considerable time in
operation, leave it to cool as temperature of the outer surface may be in excess of 60 °C.
1. Drain off the oil from the pump.
NOTE
: For a description of how to drain off the oil, see
the Unscheduled Maintenance Card No. 102.
2. Unscrew the securing screws (71) and disconnect the
flange (85) from the casing.
3. Take out the OR gasket (87) and the sight glass
(86).
NOTE
: When reassembling, replace the gaskets that
you have stripped down.
CAUTION
: When reassembly is complete, proceed to
fill the pump with oil again following the instructions of
Unscheduled Maintenance Card No. 102.
action area