VACSOUND ECO – Operating and maintenance instructions
34
Unscheduled maintenance
Card No.
107
Pump type:
VACSOUND ECO D12, D18, D28
Frequency:
when damaged
Time:
1 hour
Machine
status:
S
Type of action:
Disassembly
Item:
Oil pump
Materials required
Equipment required
Oil pump
Mechanical tools
WARNING
: Machine safety: disconnect all power lines. Hang the card “MACHINE
UNDERGOING MAINTENANCE - DO NOT POWER ON” from the main breaker switch. When
finished, remove the safety warning.
WARNING
: If you have to perform maintenance on the pump after a considerable time in
operation, leave it to cool as temperature of the outer surface may be in excess of 60 °C.
1. Drain off all the oil from the pump.
NOTE
: For a description of how to drain the oil from the pump, see the Unscheduled
Maintenance Card No. 102.
2. Disconnect the discharge flange from its piping.
3. Unscrew the nuts (3) and remove the casing from the pump (75).
action area