i Cod. 80000370 – 22.08.2012
PROGRAMMING OF THE CONTROLLER (DIXELL XR50CX)
Attention
: the access to the programming menus and the modification of the parameters are
exclusively reserved to installation and maintenance personnel. A wrong or improper modification of the
parameters can lead to malfunctions and/or to a lack of performances.
Parameters categories and access to the menus
Working parameters are grouped in two different categories:
1.
“Pr1” parameters
(user level – see parameter table)
2.
“Pr2” parameters
(Hidden Menu – see parameter table)
Access and setting type “Pr1” parameters (user level)
To change the parameter’s value operate as follows:
-
Enter the Programming mode by pressing the
SET
+
DOWN
buttons for 3sec. (the “°C” or “°F” LED
starts blinking).
-
Select the required parameter. Press the
SET
button to display its value.
-
Use
UP
or
DOWN
buttons to change the parameter value.
-
Press
SET
to store the new value and move to the following parameter.
-
To exit: Press
SET
+
UP
or wait 15sec. without pressing a key.
NOTE: the set value is stored even when the procedure is exited by waiting the time-out period.
Access and setting type “Pr2” parameters (Hidden Menu)
-
Enter the Programming mode by pressing the
SET
+
DOWN
buttons for 3sec. (the “°C” or “°F” LED
starts blinking on the display).
-
Release the buttons, then push them again and keep pressed for more than 7sec. The
Pr2
label will
be displayed immediately followed by the
HY
parameter (first parameter of the list). The complete
list of parameters is now accessible and modifiable.
-
Select the required parameter scrolling the list with the
UP
or
DOWN
buttons.
-
Press the
SET
button to display the value
-
Use
UP
or
DOWN
to change the parameter value.
-
Press
SET
to store the new value and move to the following parameter.
-
To exit: Press
SET
+ o or wait 15s without pressing any button.
NOTE: the set value is stored even when the procedure is exited by waiting the time-out period.
Attention :
in case of a power black-out before the save procedure, all parameter changes
previously applied are lost.
Содержание GIANO 70
Страница 16: ...11 Cod 80000080c 17 07 2018...
Страница 24: ...19 Cod 80001850 10 11 2014 X8 X8 X4 X4 X2 X2 4 5 6 7 8 9 10 11...
Страница 25: ...20 Cod 80001850 10 11 2014 X8 X4 12 13 14...
Страница 27: ...22 Cod 80002380a 04 08 2015 7 8 9 1 2 X2 10 11 X2 X2 12 13 14 M6 X20 X6 Only for Gemini Only for Gemini...
Страница 28: ...23 Cod 80002380a 04 08 2015 15 16 17 X2 18 X2 20 21 22 10 18 19...
Страница 29: ...24 Cod 80002380a 04 08 2015 23 24 X2 26 X2 27 X2 28 24 27 25...
Страница 45: ......
Страница 46: ......
Страница 47: ......