CONTROL PANEL (DIXELL XR50CX)
This cabinet with built-in condensing unit has a control panel equipped with an electronic controller
(pos.2)
DIXELL mod. XR50CX
. This microprocessor-based controller is equipped with a LED display and has been
specifically developed for the management of refrigerating units, display cabinets and showcases. The LED
display contains 3 digits and a decimal point, for an easy reading of temperatures, parameters and their
respective values. The display also contains a set of graphic icons, for an intuitive graphical representation
of the working status of the cabinet. The controller is also characterized by a 6-buttons keypad, which
allows the activation/deactivation of the main functions, and the storage/modification of the working
parameters. The switch-on and switch-off of the cabinet is operated, according to the model, through a
differential isolator (also known as RCCB, Residual Current Circuit Breaker – see pos. 1)
or through a
bipolar main-switch
(pos.3).
Switch-on and switch-off of the unit
In order to switch-on the cabinet and the related functions, turn the isolator switch
(safety circuit breaker – pos.1) or the bipolar switch (pos.3) to “ON” or in
“condition 1” or in “red position” (according the possible different kind of switch
installed). At the switch-on, the display will show all icons and the 3-digits panel for
few seconds, then the current temperature and the compressor status. To switch-off the unit ,
turn the isolator switch/bipolar switch to “OFF” or in condition “0” or in “green condition”.
Attention:
in case of cleaning and/or maintenance operations it is necessary to rigorously observe the
requirements and instructions provided in the section “General recommendations”
Attention
: for some models, at the switch-on of the unit the starting of the compressor is intentionally
delayed (parameter “odS”) by some minutes. This is a normal condition, therefore such occurrence does
not represent an anomaly or a technical fault.
Normal conditions of operation
At the switch-on of the cabinet, the controller will automatically manage the functioning of the condensing
unit, in order to reach the set-point temperature and then to keep it stable. The set-point is set in factory to
a mean value, nevertheless it could be necessary to adjust its value to make it more suitable for the
preserving temperature of the displayed product (make reference to the information indicated on the
2
1
2
3
Содержание GIANO 70
Страница 16: ...11 Cod 80000080c 17 07 2018...
Страница 24: ...19 Cod 80001850 10 11 2014 X8 X8 X4 X4 X2 X2 4 5 6 7 8 9 10 11...
Страница 25: ...20 Cod 80001850 10 11 2014 X8 X4 12 13 14...
Страница 27: ...22 Cod 80002380a 04 08 2015 7 8 9 1 2 X2 10 11 X2 X2 12 13 14 M6 X20 X6 Only for Gemini Only for Gemini...
Страница 28: ...23 Cod 80002380a 04 08 2015 15 16 17 X2 18 X2 20 21 22 10 18 19...
Страница 29: ...24 Cod 80002380a 04 08 2015 23 24 X2 26 X2 27 X2 28 24 27 25...
Страница 45: ......
Страница 46: ......
Страница 47: ......