Wiring the Optoisolated Outputs
The output power supply will be connected to Output PWR (labeled OPWR) and the power supply return will be
connected to Output GND (labeled ORET). Note that the load is wired between DO and Output GND. The wiring
diagram for Bank 0 is shown in Figure 3.6 and Bank 1 in Figure 3.7. See the Opto-Isolated Outputs for ICM-
2900/ICM-1900/AMP-19520/40 section in the Appendix for details. Complete pinouts can be found in the
respective ICM sections in the appendix: A1. ICM-2900 Interconnect Module or A3. ICM-1900 Interconnect
Chapter 3 Connecting Hardware ▫ 30
DMC-42x0 User Manual
Figure 3.6: 500mA Sourcing wiring diagrams for Bank 0, DO[8:1]
Figure 3.7: 500mA Sourcing wiring diagram for Bank 1, DO[16:9]