Encoder Position Drifts
Significant noise can be seen
on MA+ and / or MB+ encoder
signals
1. Noise
Shield encoder cables
Avoid placing power cables near
encoder cables
Avoid Ground Loops
Use differential encoders
Use ±12V encoders
Stability
SYMPTOM
DIAGNOSIS
CAUSE
REMEDY
Servo motor runs away when
the loop is closed.
Reversed Motor Type corrects
situation (MT -1)
1.
Wrong feedback
polarity.
Reverse Motor or Encoder Wiring
(remember to set Motor Type back to
default value: MT 1)
Motor oscillates.
2.
Too high gain or too
little damping.
Decrease KI and KP. Increase KD.
Operation
SYMPTOM
DIAGNOSIS
CAUSE
REMEDY
Controller rejects commands.
Response of controller from
TC1 diagnoses error.
1.
Anything
Correct problem reported by TC1
Motor Doesn’t Move
Response of controller from TC1
diagnoses error.
2.
Anything
Correct problem reported by SC
Error Light (Red LED)
The red error LED has multiple meanings for Galil controllers. Here is a list of reasons the error light will come on
and possible solutions:
Under Voltage
If the controller is not receiving enough voltage to power up.
Under Current
If the power supply does not have enough current, the red LED will cycle on and off along with the green power
LED.
Position Error
If any axis that is set up as a servo (MT command) has a position error value (TE) that exceeds the error limit (ER) -
the error light will come on to signify there is an axis that has exceeded the position error limit. Use a DP*=0 to set
all encoder positions to zero or a SH (Servo Here) command to eliminate position error.
Invalid Firmware
If the controller is interrupted during a firmware update or an incorrect version of firmware is installed - the error
light will come on. The prompt will show up as a greater than sign “>” instead of the standard colon “:” prompt.
Use GalilTools software to install the correct version of firmware to fix this problem.
Self Test
During the first few seconds of power up, it is normal for the red LED to turn on while it is performing a self test. If
the self test detects a problem such as corrupted memory or damaged hardware - the error light will stay on to
signal a problem with the board. To fix this problem, a Master Reset may be required. The Master Reset will set
Chapter 9 Troubleshooting ▫ 153
DMC-42x0 User Manual
Содержание DMC-42 0 Series
Страница 85: ...Chapter 6 Programming Motion 81 DMC 42x0 User Manual Figure 6 14 ECAM cycle with Z axis as master...
Страница 195: ...ICM 2900 PCB Layout Appendices 191 DMC 42x0 User Manual...
Страница 205: ...CB 50 100 Drawings Appendices 201 DMC 42x0 User Manual...
Страница 206: ...Appendices 202 DMC 42x0 User Manual...
Страница 207: ...Appendices 203 DMC 42x0 User Manual...
Страница 208: ...Appendices 204 DMC 42x0 User Manual...
Страница 209: ...Appendices 205 DMC 42x0 User Manual...
Страница 210: ...Appendices 206 DMC 42x0 User Manual...
Страница 211: ...Appendices 207 DMC 42x0 User Manual...
Страница 214: ...CB 50 80 Drawing Appendices 210 DMC 42x0 User Manual...
Страница 215: ...Appendices 211 DMC 42x0 User Manual...